Cristina Ariadna Nicula, Anca Maria Rednik, Ariadna Patricia Nicula, Adriana Elena Bulboacă, Dorin Nicula, Karin Ursula Horvath
{"title":"Long term visual outcomes in cataract surgery with bilateral implantation of the Extended Depth of Focus Intraocular Lens - Mini Well Ready type.","authors":"Cristina Ariadna Nicula, Anca Maria Rednik, Ariadna Patricia Nicula, Adriana Elena Bulboacă, Dorin Nicula, Karin Ursula Horvath","doi":"10.22336/rjo.2022.58","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To evaluate the refractive results, visual outcomes and patients' satisfaction of a new extended depth-of-focus (EDOF) intraocular lens (IOL). <b>Setting:</b> Oculens Clinic, Cluj-Napoca, Romania. <b>Design:</b> Retrospective, single-center, observational study. <b>Methods:</b> 104 eyes of 52 patients undergoing cataract surgery with implantation of the Mini Well Ready EDOF-IOL (SIFI, Catania, Italy) were included in the study. Visual acuity at distance, intermediate and near was evaluated at 1, 6 and 12 months. Refractive results, contrast sensitivity, defocus curve and photic phenomena were also assessed. <b>Results:</b> The mean age of patients was 66.04±7.82. A significant reduction of the spherical equivalent and improvement of corrected distance visual acuity (CDVA) was observed (p<0.0001) after the surgery. All eyes obtained a CDVA of 0.5 or better at one month. All eyes achieved a corrected intermediate visual acuity (CIVA) of 0.5 or better and a corrected near visual acuity (CNVA) of 0.5 or better. At 12 months the spherical equivalent was within -0.5- +0.5 diopters (D). <b>Conclusions:</b> The EDOF-IOL offers good visual outcomes at distance, intermediate and near vision, providing an adequate contrast sensitivity and low rate of visual disturbances.</p>","PeriodicalId":21385,"journal":{"name":"Romanian journal of ophthalmology","volume":"66 4","pages":"317-325"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9773115/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Romanian journal of ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22336/rjo.2022.58","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose: To evaluate the refractive results, visual outcomes and patients' satisfaction of a new extended depth-of-focus (EDOF) intraocular lens (IOL). Setting: Oculens Clinic, Cluj-Napoca, Romania. Design: Retrospective, single-center, observational study. Methods: 104 eyes of 52 patients undergoing cataract surgery with implantation of the Mini Well Ready EDOF-IOL (SIFI, Catania, Italy) were included in the study. Visual acuity at distance, intermediate and near was evaluated at 1, 6 and 12 months. Refractive results, contrast sensitivity, defocus curve and photic phenomena were also assessed. Results: The mean age of patients was 66.04±7.82. A significant reduction of the spherical equivalent and improvement of corrected distance visual acuity (CDVA) was observed (p<0.0001) after the surgery. All eyes obtained a CDVA of 0.5 or better at one month. All eyes achieved a corrected intermediate visual acuity (CIVA) of 0.5 or better and a corrected near visual acuity (CNVA) of 0.5 or better. At 12 months the spherical equivalent was within -0.5- +0.5 diopters (D). Conclusions: The EDOF-IOL offers good visual outcomes at distance, intermediate and near vision, providing an adequate contrast sensitivity and low rate of visual disturbances.
目的:评价新型扩展焦深人工晶状体(IOL)的屈光效果、视力及患者满意度。地点:罗马尼亚克卢日纳波卡的眼科诊所。设计:回顾性、单中心、观察性研究。方法:对52例行白内障手术并植入Mini Well Ready EDOF-IOL (SIFI, Catania, Italy)的104眼患者进行研究。分别于1个月、6个月和12个月时对远、中、近视力进行评估。并对折射结果、对比灵敏度、离焦曲线和光现象进行了评价。结果:患者平均年龄66.04±7.82岁。结论:EDOF-IOL具有良好的远视、中视和近视效果,具有足够的对比灵敏度和较低的视觉干扰率。