{"title":"Harmonic analysis of traction power supply system: case study of Addis Ababa light rail transit","authors":"Shimelis Atli Assefa,&nbsp;Asegid Belay Kebede,&nbsp;Demissu Legese","doi":"10.1049/els2.12019","DOIUrl":null,"url":null,"abstract":"<p>Addis Ababa, the capital of Ethiopia, inaugurated the first electrified light rail transitsystem 4 years ago in September 2015, which makes it the first of its kind in sub-Saharan and eastern African countries. The railway line has a total length of 34.25 km with 39 passenger stations and 19 traction substations. Currently, the performance of the traction power supply system degraded severely due to the existence of harmonics in the traction network. Realizing the above problem, the harmonic analysis of Addis Ababa light rail transit electrified power supply system is presented. The analysis is performed on one of the substations called ‘Lideta’ rectifier substation. To this end, mathematical modelling and analysis of the traction main components such as the catenary, the traction transformer, the traction rectifier and the load have been done. Finally, MATLAB simulation has been performed, and the result comes with a significant reduction in harmonic distortion, which is far below the 5% limits of IEEE standard.</p>","PeriodicalId":48518,"journal":{"name":"IET Electrical Systems in Transportation","volume":"11 4","pages":"391-404"},"PeriodicalIF":1.9000,"publicationDate":"2021-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/els2.12019","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IET Electrical Systems in Transportation","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/els2.12019","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Addis Ababa, the capital of Ethiopia, inaugurated the first electrified light rail transitsystem 4 years ago in September 2015, which makes it the first of its kind in sub-Saharan and eastern African countries. The railway line has a total length of 34.25 km with 39 passenger stations and 19 traction substations. Currently, the performance of the traction power supply system degraded severely due to the existence of harmonics in the traction network. Realizing the above problem, the harmonic analysis of Addis Ababa light rail transit electrified power supply system is presented. The analysis is performed on one of the substations called ‘Lideta’ rectifier substation. To this end, mathematical modelling and analysis of the traction main components such as the catenary, the traction transformer, the traction rectifier and the load have been done. Finally, MATLAB simulation has been performed, and the result comes with a significant reduction in harmonic distortion, which is far below the 5% limits of IEEE standard.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
牵引供电系统谐波分析——以亚的斯亚贝巴轻轨交通为例
四年前的2015年9月,埃塞俄比亚首都亚的斯亚贝巴开通了首个电气化轻轨系统,这是撒哈拉以南非洲和东非国家的首个电气化轻轨系统。该线全长34.25公里,设有39个客运站和19个牵引变电所。目前,由于牵引网络中谐波的存在,导致牵引供电系统的性能严重下降。针对上述问题,对亚的斯亚贝巴轻轨供电系统进行了谐波分析。分析是在一个名为“Lideta”整流变电站的变电站上进行的。为此,对牵引链线、牵引变压器、牵引整流器、牵引负载等牵引主要部件进行了数学建模和分析。最后,进行了MATLAB仿真,结果表明谐波失真明显降低,远低于IEEE标准的5%限值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.80
自引率
4.30%
发文量
18
审稿时长
29 weeks
期刊最新文献
Multiresolution Models of DC Traction Power Supply Systems With Reversible Substations A Preliminary Study on 2D Convolutional Neural Network-Based Discontinuous Rail Position Classification for Detection on Rail Breaks Using Distributed Acoustic Sensing Data Research on Electromagnetic Impact of High-Power Direct Drive Permanent Magnet Synchronous Motor on Track Circuit E-Gear Functionality Based on Mechanical Relays in Permanent Magnet Synchronous Machines Dynamic Distribution of Rail Potential with Regional Insulation Alteration in Multi-Train Urban Rail Transit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1