Performance of X-ray detectors with SiPM readout in cargo accelerator-based inspection systems

S. Vinogradov, A. Arodzero, R. Lanza
{"title":"Performance of X-ray detectors with SiPM readout in cargo accelerator-based inspection systems","authors":"S. Vinogradov, A. Arodzero, R. Lanza","doi":"10.1109/NSSMIC.2013.6829597","DOIUrl":null,"url":null,"abstract":"Existing requirements for high throughput cargo radiography inspection include high resolution images (better than 5 mm line pair resolution), penetration beyond 400 mm steel equivalent, material discrimination (organic, inorganic, high Z), high scan speeds (> 10kph, up to 60kph), low dose and small radiation exclusion zone; all in a cost effective system. To meet and exceed these requirements research into a number of new radiography methods has been initiated. Novel concepts relying on intrapulse modulated energy X-ray sources, mono-energetic gamma-ray sources, and new types of fast X-ray detectors, Scintillation-Cherenkov Detectors, are expected to be more beneficial being combined with unique features of Silicon Photomultiplier (SiPM) technology.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"7 9-10","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2013.6829597","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

Abstract

Existing requirements for high throughput cargo radiography inspection include high resolution images (better than 5 mm line pair resolution), penetration beyond 400 mm steel equivalent, material discrimination (organic, inorganic, high Z), high scan speeds (> 10kph, up to 60kph), low dose and small radiation exclusion zone; all in a cost effective system. To meet and exceed these requirements research into a number of new radiography methods has been initiated. Novel concepts relying on intrapulse modulated energy X-ray sources, mono-energetic gamma-ray sources, and new types of fast X-ray detectors, Scintillation-Cherenkov Detectors, are expected to be more beneficial being combined with unique features of Silicon Photomultiplier (SiPM) technology.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
货物加速器检测系统中具有SiPM读数的x射线探测器的性能
现有的高吞吐量货物射线照相检查要求包括高分辨率图像(优于5毫米线对分辨率),穿透超过400毫米钢当量,材料识别(有机,无机,高Z),高扫描速度(> 10kph,最高60kph),低剂量和小辐射禁区;所有这些都在一个具有成本效益的系统中。为了满足和超越这些要求,已经开始了对一些新的放射照相方法的研究。基于脉冲内调制能量x射线源、单能量伽玛射线源和新型快速x射线探测器闪烁切伦科夫探测器的新概念,与硅光电倍增管(SiPM)技术的独特特性相结合,预计将更加有益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Scientific Trigger Unit for space-based real-time gamma ray burst detection I - Scientific software model and simulations Study on two-cell rf-deflector cavity for ultra-short electron bunch measurement Applications of many-core technologies to on-line event reconstruction in High Energy Physics experiments Optimization of the gas system in the CMS RPC detector at the LHC Performance of the ATLAS calorimeter trigger in the LHC Run 1 data taking period
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1