{"title":"Performance of X-ray detectors with SiPM readout in cargo accelerator-based inspection systems","authors":"S. Vinogradov, A. Arodzero, R. Lanza","doi":"10.1109/NSSMIC.2013.6829597","DOIUrl":null,"url":null,"abstract":"Existing requirements for high throughput cargo radiography inspection include high resolution images (better than 5 mm line pair resolution), penetration beyond 400 mm steel equivalent, material discrimination (organic, inorganic, high Z), high scan speeds (> 10kph, up to 60kph), low dose and small radiation exclusion zone; all in a cost effective system. To meet and exceed these requirements research into a number of new radiography methods has been initiated. Novel concepts relying on intrapulse modulated energy X-ray sources, mono-energetic gamma-ray sources, and new types of fast X-ray detectors, Scintillation-Cherenkov Detectors, are expected to be more beneficial being combined with unique features of Silicon Photomultiplier (SiPM) technology.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"7 9-10","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2013.6829597","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19
Abstract
Existing requirements for high throughput cargo radiography inspection include high resolution images (better than 5 mm line pair resolution), penetration beyond 400 mm steel equivalent, material discrimination (organic, inorganic, high Z), high scan speeds (> 10kph, up to 60kph), low dose and small radiation exclusion zone; all in a cost effective system. To meet and exceed these requirements research into a number of new radiography methods has been initiated. Novel concepts relying on intrapulse modulated energy X-ray sources, mono-energetic gamma-ray sources, and new types of fast X-ray detectors, Scintillation-Cherenkov Detectors, are expected to be more beneficial being combined with unique features of Silicon Photomultiplier (SiPM) technology.