Implementing distributed generation to mitigate under-frequency load shedding

W. Helmy, Y. Hegazy, M. A. Mostafa, M. Badr
{"title":"Implementing distributed generation to mitigate under-frequency load shedding","authors":"W. Helmy, Y. Hegazy, M. A. Mostafa, M. Badr","doi":"10.1109/MEPCON.2008.4562369","DOIUrl":null,"url":null,"abstract":"This paper proposes a strategy for employing distributed generation units to stop the frequency deterioration resulting from severe disturbances in electrical distribution systems rather than relying on load shedding as the obtainable treatment. Also, sufficient comparison is made between both treatment methods. Low order system frequency response model (SFR) is used to estimate the frequency deviation. The model parameters are adjusted when the system is equipped with the distribution generation units. The amounts of load to be shed or the power to be delivered by DGs are compared and the treatment method that presents better dynamic response specifications is recommended.","PeriodicalId":236620,"journal":{"name":"2008 12th International Middle-East Power System Conference","volume":"77 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 12th International Middle-East Power System Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEPCON.2008.4562369","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

This paper proposes a strategy for employing distributed generation units to stop the frequency deterioration resulting from severe disturbances in electrical distribution systems rather than relying on load shedding as the obtainable treatment. Also, sufficient comparison is made between both treatment methods. Low order system frequency response model (SFR) is used to estimate the frequency deviation. The model parameters are adjusted when the system is equipped with the distribution generation units. The amounts of load to be shed or the power to be delivered by DGs are compared and the treatment method that presents better dynamic response specifications is recommended.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
实施分布式发电以减轻低频负荷下降
本文提出了一种利用分布式发电机组来阻止配电系统中由严重干扰引起的频率劣化的策略,而不是依靠减载作为可获得的处理方法。并对两种处理方法进行了充分的比较。采用低阶系统频响模型(SFR)估计频率偏差。当系统配备配电发电机组时,对模型参数进行调整。比较了dg的减载量和输出功率,推荐了动态响应性能更好的处理方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Implementing distributed generation to mitigate under-frequency load shedding Generation coordination for transient stability enhancement using particle swarm optimization Modeling and simulation of Photovoltaic/Wind Hybrid Electric Power System Interconnected with electrical utility Space-charge measurement in composite dielectrics Design of the instrument current transformer for high frequency high power applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1