Sodium Fluoride tubes versus plain tubes for In vitro blood glucose analysis

Nawoda Hewage, Lakshani Y. Dassanayaka, Deepthi Inoka Uluwaduge
{"title":"Sodium Fluoride tubes versus plain tubes for In vitro blood glucose analysis","authors":"Nawoda Hewage, Lakshani Y. Dassanayaka, Deepthi Inoka Uluwaduge","doi":"10.4038/CJMS.V55I2.4936","DOIUrl":null,"url":null,"abstract":"Background: In terms of diagnosis and management of diabetes mellitus, the most commonly requested core biochemistry test worldwide is measurement of glucose in blood. Despite the wide use of sodium fluoride (NaF) as the specimen preservative, its use has been critically questioned. Objective: This study investigated the stability of glucose in blood obtained into plain tubes in comparison with sodium fluoride/potassium oxalate (NaF/K2C2O4) tubes in a routine laboratory setup. Methods: Sixty one pairs of blood specimens were collected into plain tubes and NaF/K2C2O4 tubes. Following separation of plasma (NaF/K2C2O4 tubes) and serum (plain tubes), glucose concentration was measured. Five determinants were obtained; the baseline glucose value, glucose concentrations at one, two, four and six hours after collection of blood into NaF/K2C2O4 or plain tubes. Results: A high rate of haemolysis was observed in NaF/K2C2O4 tubes when compared with that of plain tubes (11% vs. 4%). No effect of tube type on serum/plasma glucose concentration (p>.05) was noted until two hours post collection. A significant reduction (p Conclusion: Plain tubes are a better option for collection and processing blood in measurement of glucose if the separation is achieved within a reasonable time period.","PeriodicalId":253405,"journal":{"name":"Ceylon Journal of Medical Science","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceylon Journal of Medical Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4038/CJMS.V55I2.4936","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: In terms of diagnosis and management of diabetes mellitus, the most commonly requested core biochemistry test worldwide is measurement of glucose in blood. Despite the wide use of sodium fluoride (NaF) as the specimen preservative, its use has been critically questioned. Objective: This study investigated the stability of glucose in blood obtained into plain tubes in comparison with sodium fluoride/potassium oxalate (NaF/K2C2O4) tubes in a routine laboratory setup. Methods: Sixty one pairs of blood specimens were collected into plain tubes and NaF/K2C2O4 tubes. Following separation of plasma (NaF/K2C2O4 tubes) and serum (plain tubes), glucose concentration was measured. Five determinants were obtained; the baseline glucose value, glucose concentrations at one, two, four and six hours after collection of blood into NaF/K2C2O4 or plain tubes. Results: A high rate of haemolysis was observed in NaF/K2C2O4 tubes when compared with that of plain tubes (11% vs. 4%). No effect of tube type on serum/plasma glucose concentration (p>.05) was noted until two hours post collection. A significant reduction (p Conclusion: Plain tubes are a better option for collection and processing blood in measurement of glucose if the separation is achieved within a reasonable time period.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
氟化钠试管与普通试管用于体外血糖分析
背景:在糖尿病的诊断和治疗方面,世界范围内最常用的核心生化检测是血葡萄糖的测定。尽管氟化钠(NaF)作为标本防腐剂被广泛使用,但它的使用受到了严格的质疑。目的:研究普通试管与氟化钠/草酸钾(NaF/K2C2O4)试管的血糖稳定性。方法:采集61对血液标本,分别分为普通管和NaF/K2C2O4管。血浆(NaF/K2C2O4管)和血清(普通管)分离后,测定葡萄糖浓度。得到五个决定因素;NaF/K2C2O4或普通管采血后1、2、4和6小时的基线血糖值和葡萄糖浓度。结果:NaF/K2C2O4管溶血率高于普通管(11% vs. 4%)。试管类型对血清/血浆葡萄糖浓度没有影响(p> 0.05),直到采集后2小时。结论:如果在合理的时间内实现分离,平管是采集和处理血液中葡萄糖测量的更好选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Colombo Medical Congress 2023 - Research Excellence & Beyond: Translating Research into Practice Data and technology driven learning health systems for low and middle income countries Treatment failure in cutaneous leishmaniasis in Sri Lanka – Is it for real? Misinterpretation of Chronic Kidney Disease (CKD) staging in patients with diabetes: creatinine estimation method as a source of error Supporting affordable healthcare through innovative research
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1