{"title":"Measuring of Polarization and Ohmic Potentials for the Diagnostics of Corrosion Protection of the Metal Structures","authors":"R. Dzhala","doi":"10.33552/mcms.2018.01.000503","DOIUrl":null,"url":null,"abstract":"The polarization potential (РР) is regarded as the main criterion of corrosion protection of metal structures in conducting media. However, the potential between the reference electrode and the metal of the protected structure is measured with a voltmeter and contains, in addition to the polarization component, the Ohmic drop of the voltage. But, only the polarization of the surface causes the effect of cathodic protection. Therefore, the Ohmic component should be removed from the measured potential difference for the precise control of the protected structure. To solve the problem of measuring PP is known methods of compensating, relaxation, auxiliary electrodes and calculations, which have disadvantages.","PeriodicalId":297187,"journal":{"name":"Modern Concepts in Material Science","volume":"33 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modern Concepts in Material Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33552/mcms.2018.01.000503","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The polarization potential (РР) is regarded as the main criterion of corrosion protection of metal structures in conducting media. However, the potential between the reference electrode and the metal of the protected structure is measured with a voltmeter and contains, in addition to the polarization component, the Ohmic drop of the voltage. But, only the polarization of the surface causes the effect of cathodic protection. Therefore, the Ohmic component should be removed from the measured potential difference for the precise control of the protected structure. To solve the problem of measuring PP is known methods of compensating, relaxation, auxiliary electrodes and calculations, which have disadvantages.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
偏振电位和欧姆电位的测量在金属结构腐蚀防护诊断中的应用
极化电位(РР)是导电介质中金属结构腐蚀防护的主要判据。但是,参考电极和受保护结构的金属之间的电位是用电压表测量的,除了极化成分外,还包含电压的欧姆降。但是,只有表面的极化才能起到阴极保护的作用。因此,为了精确控制受保护结构,欧姆分量应该从测量的电位差中去除。为了解决测量PP的问题,已知的方法有补偿法、弛豫法、辅助电极法和计算法,这些方法都有缺点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Tool Wear Influence on The Fatigue Life of Lathe Processed Specimens of 1.6310 Steel Materials Science, Circularity and Sustainability: The need for Fundamental Change in Materials Science Research. A Way out of World-Wide Indentation Dichotomy in Materials’ Science Systematic Methods to Enhance the Life of Mechanical System Such as Compressor Subjected to Repetitive Impact Load The Effect of Durability and Corrosion Behavior on the Concrete Treated with Chemical Inhibitor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1