{"title":"System for core fault detection of AC electric machines, based on magnetic field scanning","authors":"W. Rams, M. Rad","doi":"10.1109/ICELMACH.2014.6960406","DOIUrl":null,"url":null,"abstract":"A new method of detecting insulation faults in cores of AC machines is outlined. The method involves the measurements of the magnetic field near the surface of the core, using a number of parallel electronic field meters. It is demonstrated that the new method does not share the disadvantages of other methods as it does not require a high current source and long operation time compared with the thermal method. Besides, it offers a better resolution than the ELCID method. A dedicated computer program is used to measure and visualize results, which can be displayed in the form similar to those obtained from a thermal camera. The method is applicable both to synchronous generators and induction machines.","PeriodicalId":288960,"journal":{"name":"2014 International Conference on Electrical Machines (ICEM)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Electrical Machines (ICEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2014.6960406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A new method of detecting insulation faults in cores of AC machines is outlined. The method involves the measurements of the magnetic field near the surface of the core, using a number of parallel electronic field meters. It is demonstrated that the new method does not share the disadvantages of other methods as it does not require a high current source and long operation time compared with the thermal method. Besides, it offers a better resolution than the ELCID method. A dedicated computer program is used to measure and visualize results, which can be displayed in the form similar to those obtained from a thermal camera. The method is applicable both to synchronous generators and induction machines.