Liver Splitting Using 2 Points for Liver Graft Volumetry

Jeong-Joo Seo, Jong-won Park
{"title":"Liver Splitting Using 2 Points for Liver Graft Volumetry","authors":"Jeong-Joo Seo, Jong-won Park","doi":"10.3745/KIPSTB.2012.19B.2.123","DOIUrl":null,"url":null,"abstract":"This paper proposed a method to separate a liver into left and right liver lobes for simple and exact volumetry of the river graft at abdominal MDCT(Multi-Detector Computed Tomography) image before the living donor liver transplantation. A medical team can evaluate an accurate river graft with minimized interaction between the team and a system using this algorithm for ensuring donor`s and recipient`s safe. On the image of segmented liver, 2 points(PMHV: a point in Middle Hepatic Vein and PPV: a point at the beginning of right branch of Portal Vein) are selected to separate a liver into left and right liver lobes. Middle hepatic vein is automatically segmented using PMHV, and the cutting line is decided on the basis of segmented Middle Hepatic Vein. A liver is separated on connecting the cutting line and PPV. The volume and ratio of the river graft are estimated. The volume estimated using 2 points are compared with a manual volume that diagnostic radiologist processed and estimated and the weight measured during surgery to support proof of exact volume. The mean standard deviation of the differences between the actual weights and the estimated volumes was in the case of manual segmentation and in the case of 2 points method. The correlation coefficient between the actual weight and the manually estimated volume is 0.79, and the correlation coefficient between the actual weight and the volume estimated using 2 points is 0.87. After selection the 2 points, the time involved in separation a liver into left and right river lobe and volumetry of them is measured for confirmation that the algorithm can be used on real time during surgery. The mean standard deviation of the process time is per 1 data set ().","PeriodicalId":122700,"journal":{"name":"The Kips Transactions:partb","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Kips Transactions:partb","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3745/KIPSTB.2012.19B.2.123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper proposed a method to separate a liver into left and right liver lobes for simple and exact volumetry of the river graft at abdominal MDCT(Multi-Detector Computed Tomography) image before the living donor liver transplantation. A medical team can evaluate an accurate river graft with minimized interaction between the team and a system using this algorithm for ensuring donor`s and recipient`s safe. On the image of segmented liver, 2 points(PMHV: a point in Middle Hepatic Vein and PPV: a point at the beginning of right branch of Portal Vein) are selected to separate a liver into left and right liver lobes. Middle hepatic vein is automatically segmented using PMHV, and the cutting line is decided on the basis of segmented Middle Hepatic Vein. A liver is separated on connecting the cutting line and PPV. The volume and ratio of the river graft are estimated. The volume estimated using 2 points are compared with a manual volume that diagnostic radiologist processed and estimated and the weight measured during surgery to support proof of exact volume. The mean standard deviation of the differences between the actual weights and the estimated volumes was in the case of manual segmentation and in the case of 2 points method. The correlation coefficient between the actual weight and the manually estimated volume is 0.79, and the correlation coefficient between the actual weight and the volume estimated using 2 points is 0.87. After selection the 2 points, the time involved in separation a liver into left and right river lobe and volumetry of them is measured for confirmation that the algorithm can be used on real time during surgery. The mean standard deviation of the process time is per 1 data set ().
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肝分裂2点法肝移植体积测定
本文提出了一种将肝脏分离为左右肝叶的方法,以便在活体肝移植前在腹部MDCT(Multi-Detector Computed Tomography)图像上对肝移植物进行简单准确的体积测量。医疗团队可以通过最小化团队与系统之间的相互作用来评估准确的河流移植,并使用该算法确保供体和受体的安全。在肝脏分割图像上,选择2个点(PMHV:肝中静脉点,PPV:门静脉右支起始点)将肝脏分割成左右肝叶。利用PMHV自动分割肝中静脉,并在分割后的肝中静脉的基础上确定切割线。在连接切割线和PPV时分离肝脏。估计了河流嫁接的体积和比例。使用2点估计的体积与诊断放射科医生处理和估计的人工体积以及手术期间测量的重量进行比较,以支持精确体积的证明。实际权值与预估体积差的平均标准差分别为手工分割和2点法分割。实际重量与人工估算体积的相关系数为0.79,实际重量与2点估算体积的相关系数为0.87。选择2个点后,测量肝脏左右叶分离所需的时间和体积,验证该算法可以在手术中实时使用。过程时间的平均标准差为每1个数据集()。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Query Expansion Based on Word Graphs Using Pseudo Non-Relevant Documents and Term Proximity Morpheme Recovery Based on Naïve Bayes Model Automatic Identification of the Lumen Border in Intravascular Ultrasound Images Retrieval Model Based on Word Translation Probabilities and the Degree of Association of Query Concept Multidimensional Optimization Model of Music Recommender Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1