STUDI KASUS: ANALISIS PROSEDUR PEMERIKSAAN MR IMAGING ORBITA DENGAN MEDIA KONTRAS PADA KASUS RETINOBLASTOMA

Herna Utami, Fani Susanto, Redha Okta Silfina
{"title":"STUDI KASUS: ANALISIS PROSEDUR PEMERIKSAAN MR IMAGING ORBITA DENGAN MEDIA KONTRAS PADA KASUS RETINOBLASTOMA","authors":"Herna Utami, Fani Susanto, Redha Okta Silfina","doi":"10.54973/miror.v2i2.256","DOIUrl":null,"url":null,"abstract":"Diagnosis of orbital is recommended for orbital MRI examinations, on of the pathology is retinoblastoma. orbital organs contain a lot of soft tissues so the orbital MRI is one of the right choices because it can appear anatomically and pathologically in a cross-sectional orbital, in two dimensions and three dimensions. Examination protocols on orbital MRI in retinoblastoma cases have several sequences in pre- and post-contrast agent. The purposes of this research was to determine the orbits MRI procedure in the retinoblastoma case.The Methods of this research is a descriptive of qualitative with case study method. The data were collected in unit of radiology DR. Saiful Anwar Malang by using observation method, documentation and interview of radiolog and radiographers. Data analyzed by using presented and data reduction to get the conclusion and suggestion. The results is an orbital MRI examination is concerned with MRI safety with patient screening and informed consent. The protocol for pre-contrast agent orbital MRI was T1 3D TSE axial, T2 TSE axial, DWI axial, T2 TSE fat saturated axial , and T2 DRIVE axial. On post-contrast agent using sagittal T1 FFE sequences, T1 3D TSE axial . The use of slice thickness is 3mm and 1mm in 3D image, 2D T2 DRIVE and 2D T1 FFE post contrast. gadolinium contrast agent as much as 5 mmol/10ml injection intravenously. The selection of sequences in the protocol of orbital MRI can produce detailed orbital anatomy images and provide sufficient clinical information to diagnose retinoblastoma.","PeriodicalId":121704,"journal":{"name":"Medical Imaging and Radiation Protection Research (MIROR) Journal","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Imaging and Radiation Protection Research (MIROR) Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54973/miror.v2i2.256","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Diagnosis of orbital is recommended for orbital MRI examinations, on of the pathology is retinoblastoma. orbital organs contain a lot of soft tissues so the orbital MRI is one of the right choices because it can appear anatomically and pathologically in a cross-sectional orbital, in two dimensions and three dimensions. Examination protocols on orbital MRI in retinoblastoma cases have several sequences in pre- and post-contrast agent. The purposes of this research was to determine the orbits MRI procedure in the retinoblastoma case.The Methods of this research is a descriptive of qualitative with case study method. The data were collected in unit of radiology DR. Saiful Anwar Malang by using observation method, documentation and interview of radiolog and radiographers. Data analyzed by using presented and data reduction to get the conclusion and suggestion. The results is an orbital MRI examination is concerned with MRI safety with patient screening and informed consent. The protocol for pre-contrast agent orbital MRI was T1 3D TSE axial, T2 TSE axial, DWI axial, T2 TSE fat saturated axial , and T2 DRIVE axial. On post-contrast agent using sagittal T1 FFE sequences, T1 3D TSE axial . The use of slice thickness is 3mm and 1mm in 3D image, 2D T2 DRIVE and 2D T1 FFE post contrast. gadolinium contrast agent as much as 5 mmol/10ml injection intravenously. The selection of sequences in the protocol of orbital MRI can produce detailed orbital anatomy images and provide sufficient clinical information to diagnose retinoblastoma.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
案例研究:根据视网膜母细胞瘤的对比度对or字节先生的检查程序分析
眼眶MRI检查建议诊断眼眶,病理之一为视网膜母细胞瘤。眼眶器官包含了很多软组织所以眼眶MRI是一个正确的选择因为它可以在解剖上和病理上出现在眼眶的横截面上,在二维和三维上。视网膜母细胞瘤病例的眼眶MRI检查方案在造影剂前和后有几个顺序。本研究的目的是确定眼眶MRI在视网膜母细胞瘤病例中的应用。本研究的方法是描述性定性结合个案研究法。资料收集于放射科赛弗·安瓦尔·玛朗医师单位,采用观察法、文献资料法及对放射科医师和放射技师的访谈。通过对数据的分析,采用呈现法和数据约简法,得出结论和建议。结果是眼眶MRI检查与患者筛查和知情同意的MRI安全性有关。造影剂眼眶MRI方案为T1 3D TSE轴位、T2 TSE轴位、DWI轴位、T2 TSE脂肪饱和轴位、T2 DRIVE轴位。在造影剂上使用矢状T1 FFE序列,T1 3D TSE轴向。使用切片厚度分别为3mm和1mm的3D图像,2D T2 DRIVE和2D T1 FFE后对比。静脉注射钆造影剂5 mmol/10ml。眼眶MRI方案中序列的选择可以产生详细的眼眶解剖图像,为视网膜母细胞瘤的诊断提供充分的临床信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
STUDI KASUS: ANALISIS PROSEDUR PEMERIKSAAN MR IMAGING ORBITA DENGAN MEDIA KONTRAS PADA KASUS RETINOBLASTOMA RADIOGRAPHIC EXAMINATION TECHNIQUES OF LUMBAL VERTEBRA IN CASE OF LOW BACK PAIN IN ISLAMIC HOSPITAL PURWOKERTO PERBANDINGAN INFORMASI CITRA ANATOMI MRA RENAL DENGAN MENGGUNAKAN METODE TIME OF FLIGHT DAN PHASE CONTRAST DI INSTALASI RADIOLOGI RSUD ARIFIN ACHMAD PROVINSI RIAU OVERVIEW OF RADIATION SAFETY MANAGEMENT SYSTEM IN RADIOLOGY FACILITY OF PETALA BUMI REGIONAL GENERAL HOSPITAL IN THE CASE OF LOW BACK PAIN LUMBOSACRAL EXAMINATION IN PANDAN ARANG HOSPITAL
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1