ENERGY EFFICIENT IMPROVEMENT OF HISTORIC BUILDINGS: A CASE STUDY IN SINOP

G. Genç, Figen Beyhan
{"title":"ENERGY EFFICIENT IMPROVEMENT OF HISTORIC BUILDINGS: A CASE STUDY IN SINOP","authors":"G. Genç, Figen Beyhan","doi":"10.38065/euroasiaorg.730","DOIUrl":null,"url":null,"abstract":"Although historical buildings are ecological with their construction systems and materials, they cannot provide necessary performance in today's comfort conditions and therefore they are abandoned and remain in a damaged or dysfunctional state. Energy efficient improvement works are carried out in historical buildings in order to bring the historical buildings today's conditions, re-use and ensure their sustainability. However, there are many limitations in these studies due to the heritage characteristics of historical buildings. With these limitations, the works to be done should be carried out with the least intervention without damaging the heritage values of the historical buildings. For this reason, it is necessary to specially select the applications to be realized within the scope of energy efficiency in historical buildings and scaling the physical effects of the applications relative to each other. In this context, in this study, it is aimed to reveal the appropriate improvement methods in order to reach the maximum energy efficiency with the least physical intervention, with the techniques suitable for the historical texture by preserving the original qualities in the historical buildings. Based on the Historic England intervention evaluation scale developed in this framework, 5 scenarios, including the current situation and 4 different design scenarios, including interventions from small to large impacts, were created on a sample historical residential building, and the data of each scenario in terms of energy consumption were obtained. Models created within the framework of the scenarios were evaluated with the Design Builder simulation program, and annual heating and cooling loads and the amount of energy consumed per total m² were obtained. Evaluations were made by comparing the energy efficiency of applications at different degrees with the graphics and tables prepared in the light of these data. As a result, suggestions have been developed regarding the interventions to be made to historical buildings according to the intervention effect sizes in the context of energy efficiency with the evaluations made.","PeriodicalId":396861,"journal":{"name":"Euroasia Journal of Mathematics, Engineering, Natural & Medical Sciences","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Euroasia Journal of Mathematics, Engineering, Natural & Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.38065/euroasiaorg.730","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Although historical buildings are ecological with their construction systems and materials, they cannot provide necessary performance in today's comfort conditions and therefore they are abandoned and remain in a damaged or dysfunctional state. Energy efficient improvement works are carried out in historical buildings in order to bring the historical buildings today's conditions, re-use and ensure their sustainability. However, there are many limitations in these studies due to the heritage characteristics of historical buildings. With these limitations, the works to be done should be carried out with the least intervention without damaging the heritage values of the historical buildings. For this reason, it is necessary to specially select the applications to be realized within the scope of energy efficiency in historical buildings and scaling the physical effects of the applications relative to each other. In this context, in this study, it is aimed to reveal the appropriate improvement methods in order to reach the maximum energy efficiency with the least physical intervention, with the techniques suitable for the historical texture by preserving the original qualities in the historical buildings. Based on the Historic England intervention evaluation scale developed in this framework, 5 scenarios, including the current situation and 4 different design scenarios, including interventions from small to large impacts, were created on a sample historical residential building, and the data of each scenario in terms of energy consumption were obtained. Models created within the framework of the scenarios were evaluated with the Design Builder simulation program, and annual heating and cooling loads and the amount of energy consumed per total m² were obtained. Evaluations were made by comparing the energy efficiency of applications at different degrees with the graphics and tables prepared in the light of these data. As a result, suggestions have been developed regarding the interventions to be made to historical buildings according to the intervention effect sizes in the context of energy efficiency with the evaluations made.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
历史建筑节能改进:以锡诺普为例
虽然历史建筑的建造系统和材料都是生态的,但它们在今天的舒适条件下无法提供必要的性能,因此它们被遗弃,处于受损或功能失调的状态。我们为历史建筑进行节能改善工程,以使历史建筑符合今天的状况,重新利用和确保其可持续发展。然而,由于历史建筑的遗产特性,这些研究存在许多局限性。由于这些限制,在进行工程时应尽量减少干预,而不损害历史建筑的文物价值。因此,有必要在历史建筑节能范围内专门选择要实现的应用,并对应用之间的物理效应进行相对缩放。在此背景下,本研究旨在揭示适当的改进方法,以最少的物理干预,以适合历史肌理的技术,在保留历史建筑的原始品质的情况下,达到最大的能源效率。基于该框架制定的Historic England干预评估量表,对样本历史住宅建筑创建了5个场景,包括现状和4个不同的设计场景,包括从小影响到大影响的干预措施,并获得了每个场景的能耗数据。使用Design Builder模拟程序对在情景框架内创建的模型进行了评估,获得了年供暖和制冷负荷以及每平方米总能耗。通过比较不同程度的应用程序的能源效率,并根据这些数据制作图形和表格,进行评价。因此,根据能源效率背景下的干预效应大小,提出了对历史建筑进行干预的建议,并进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
THERMAL PARAMETERS AND STRUCTURAL INVESTIGATIONS OF Cu-BASED SHAPE MEMORY ALLOYS IRRADIATED WITH Co-60 ENERGY EFFICIENT IMPROVEMENT OF HISTORIC BUILDINGS: A CASE STUDY IN SINOP INVESTIGATION OF MECHANICAL PROPERTIES OF PIPES WITH BUTT CURVED LAP JOINTS SUBJECTED TO TORSION A RESEARCH ON VOCATIONAL EDUCATION AND YACHT BUILDING SECTOR IN BODRUM LIVEDO RETICULARIS: CLINICAL SIGNIFICANCE AND TREATMENT
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1