A Hybrid EMC Testing Facility: Combining Transmission Line and Reverberation Chamber Measurement System

Kai Chen, Wenjun Qi, Peng Peng, Hailong Wang, Xueqi Shen, Yongjiu Zhao, Qian Xu
{"title":"A Hybrid EMC Testing Facility: Combining Transmission Line and Reverberation Chamber Measurement System","authors":"Kai Chen, Wenjun Qi, Peng Peng, Hailong Wang, Xueqi Shen, Yongjiu Zhao, Qian Xu","doi":"10.13052/2023.aces.j.380103","DOIUrl":null,"url":null,"abstract":"By combining a transmission line system (TLS) and a reverberation chamber (RC), a hybrid electromagnetic compatibility (EMC) testing facility is designed and constructed. Generally, the lowest usable frequency (LUF) of an RC is limited by its dimension, which limits the application of RCs for EMC testing at low frequencies. Therefore, to improve the field uniformity (FU) of an RC at frequencies lower than the LUF, a TLS is integrated into the RC. After optimizing the load resistance, length, and width of the TLS, the resonant frequency and electric field spikes of the hybrid system are eliminated. The FU of the E-field in the system is greatly improved in the frequency range of 0-30 MHz. Moreover, using an oscillating wall stirrer in the RC, the FU satisfies the standard (IEC 61000-4-21) above 80 MHz. Results show that combining the TLS and the RC testing system could be widely used for EMC testing in the frequency range of 0-30 MHz and 80 MHz-6 GHz.","PeriodicalId":250668,"journal":{"name":"The Applied Computational Electromagnetics Society Journal (ACES)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Applied Computational Electromagnetics Society Journal (ACES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13052/2023.aces.j.380103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

By combining a transmission line system (TLS) and a reverberation chamber (RC), a hybrid electromagnetic compatibility (EMC) testing facility is designed and constructed. Generally, the lowest usable frequency (LUF) of an RC is limited by its dimension, which limits the application of RCs for EMC testing at low frequencies. Therefore, to improve the field uniformity (FU) of an RC at frequencies lower than the LUF, a TLS is integrated into the RC. After optimizing the load resistance, length, and width of the TLS, the resonant frequency and electric field spikes of the hybrid system are eliminated. The FU of the E-field in the system is greatly improved in the frequency range of 0-30 MHz. Moreover, using an oscillating wall stirrer in the RC, the FU satisfies the standard (IEC 61000-4-21) above 80 MHz. Results show that combining the TLS and the RC testing system could be widely used for EMC testing in the frequency range of 0-30 MHz and 80 MHz-6 GHz.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种混合式电磁兼容测试设备:传输线与混响室相结合的测量系统
将传输线系统(TLS)与混响室(RC)相结合,设计并搭建了混合电磁兼容性(EMC)测试设备。一般情况下,RC的最低可用频率(LUF)受其尺寸的限制,这限制了RC在低频电磁兼容测试中的应用。因此,为了提高RC在低于LUF频率下的场均匀性(FU),在RC中集成了TLS。通过对负载电阻、长度和宽度进行优化,消除了混合系统的谐振频率和电场尖峰。在0 ~ 30 MHz的频率范围内,系统中e场的FU得到了很大的提高。此外,在RC中使用振荡壁式搅拌器,FU满足80 MHz以上的标准(IEC 61000-4-21)。结果表明,将TLS与RC测试系统相结合,可广泛用于0 ~ 30mhz和80mhz ~ 6ghz频率范围内的电磁兼容测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A 3-D Global FDTD Courant-limit Model of the Earth for Long-time-span and High-altitude Applications Uncertainty Quantification and Optimal Design of EV-WPT System Efficiency based on Adaptive Gaussian Process Regression Single-mode Condition and Bending Loss Analysis of Ultrafast Laser-inscribed Mid-infrared Waveguides in GeAsSe Chalcogenide Glass Design of Wilkinson Power Dividers with SITL Compensated Microstrip Bandpass Filters Resonant Frequency Modelling of Microstrip Antennas by Consensus Network and Student’s-T Process
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1