G. Barbosa, G. Dantas, Bianca Silva, S. M. Pinheiro, H. Santos, W. H. Vieira
{"title":"Intra-rater and Inter-instrument Reliability on Range of Movement of Active Knee Extension","authors":"G. Barbosa, G. Dantas, Bianca Silva, S. M. Pinheiro, H. Santos, W. H. Vieira","doi":"10.1590/S1980-6574201700010008","DOIUrl":null,"url":null,"abstract":"The objective of the present study was to evaluate the reliability of intra-rater and inter-instrument measures during two flexibility programs. Fifty-three active and healthy males, aged between 18 and 28 years old, were randomly included in three groups: control (Cg, n = 18), static stretching (SSg, n = 17), and dynamic stretching (DSg, n = 18). All participants underwent measurements of their active range of knee extension using manual goniometry and computerized photogrammetry, measured in four separated assessments and analyzed using the SPSS, with ((5%. Both methodologies presented very strongintra-raterreliability (ICC: 0.91(0.99; P<0.001) at all four assessments in all the groups, and the instruments showed weak (r: 0.31-0.6) to strong(r: 0.61-0.9) correlation, in the Cg (P<0.05) and strong (r: 0.61-0.9) in the SSg and DSg (P<0.01), although without differences between groups, indicating that the measures are equally reliable, regardless of interventions.","PeriodicalId":267352,"journal":{"name":"Motriz-revista De Educacao Fisica","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Motriz-revista De Educacao Fisica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S1980-6574201700010008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
The objective of the present study was to evaluate the reliability of intra-rater and inter-instrument measures during two flexibility programs. Fifty-three active and healthy males, aged between 18 and 28 years old, were randomly included in three groups: control (Cg, n = 18), static stretching (SSg, n = 17), and dynamic stretching (DSg, n = 18). All participants underwent measurements of their active range of knee extension using manual goniometry and computerized photogrammetry, measured in four separated assessments and analyzed using the SPSS, with ((5%. Both methodologies presented very strongintra-raterreliability (ICC: 0.91(0.99; P<0.001) at all four assessments in all the groups, and the instruments showed weak (r: 0.31-0.6) to strong(r: 0.61-0.9) correlation, in the Cg (P<0.05) and strong (r: 0.61-0.9) in the SSg and DSg (P<0.01), although without differences between groups, indicating that the measures are equally reliable, regardless of interventions.