The Effect of Penetration Floating Photovoltaic On – Grid in Diponegoro Education Reservoir against Power Quality Distribution Network

Karnoto Karnoto, H. Hermawan, Pangestuningtyas Diah Larasati, Ali Zaenal Abidin
{"title":"The Effect of Penetration Floating Photovoltaic On – Grid in Diponegoro Education Reservoir against Power Quality Distribution Network","authors":"Karnoto Karnoto, H. Hermawan, Pangestuningtyas Diah Larasati, Ali Zaenal Abidin","doi":"10.17977/um049v3i2p34-38","DOIUrl":null,"url":null,"abstract":"Diponegoro University is one of the universities that support the research, development, and utilization of renewable energy in Indonesia. The Diponegoro educational reservoir is one of the facilities at Diponegoro University that can be developed as a floating photovoltaic. The potential of the Diponegoro educational reservoir as a floating photovoltaic on-grid is 1.846 kWp. Penetration of floating photovoltaic in the power grid can affect the power quality of the system. This paper discusses the effect of floating photovoltaic penetration in the education reservoir in Diponegoro on the 20 kV distribution network using ETAP software. In this study, the penetration of floating photovoltaic capacity connect to the distribution network is 0%, 10%, 20%, 30%, and 40%. Penetration of floating photovoltaic can cause a decrease in power factor and losses in the distribution system. The maximum penetration of floating photovoltaic in the education reservoir in Diponegoro in the 20 kV distribution system is 30% with the injected capacity of floating photovoltaic is 1.121,3 kWp and the power factor in of the network is 0,867. Penetration over 30% can cause the system power factor to be less than the allowable power factor standard.","PeriodicalId":285860,"journal":{"name":"Frontier Energy System and Power Engineering","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontier Energy System and Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17977/um049v3i2p34-38","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Diponegoro University is one of the universities that support the research, development, and utilization of renewable energy in Indonesia. The Diponegoro educational reservoir is one of the facilities at Diponegoro University that can be developed as a floating photovoltaic. The potential of the Diponegoro educational reservoir as a floating photovoltaic on-grid is 1.846 kWp. Penetration of floating photovoltaic in the power grid can affect the power quality of the system. This paper discusses the effect of floating photovoltaic penetration in the education reservoir in Diponegoro on the 20 kV distribution network using ETAP software. In this study, the penetration of floating photovoltaic capacity connect to the distribution network is 0%, 10%, 20%, 30%, and 40%. Penetration of floating photovoltaic can cause a decrease in power factor and losses in the distribution system. The maximum penetration of floating photovoltaic in the education reservoir in Diponegoro in the 20 kV distribution system is 30% with the injected capacity of floating photovoltaic is 1.121,3 kWp and the power factor in of the network is 0,867. Penetration over 30% can cause the system power factor to be less than the allowable power factor standard.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
迪波尼戈罗教育水库渗透式浮动光伏并网对配电网质量的影响
迪波尼戈罗大学是印尼支持可再生能源研究、开发和利用的大学之一。Diponegoro教育水库是Diponegoro大学的设施之一,可以作为浮动光伏开发。Diponegoro教育水库作为浮动光伏并网水库的潜力为1.846 kWp。浮动光伏在电网中的渗透会影响系统的电能质量。本文利用ETAP软件分析了迪波涅戈罗教育水库漂浮式光伏渗透对20kv配电网的影响。在本研究中,浮动光伏容量接入配电网的渗透率分别为0%、10%、20%、30%和40%。浮动光伏的渗透可以降低配电系统的功率因数和损耗。Diponegoro教育水库在20kv配电系统中浮动光伏最大渗透率为30%,浮动光伏注入容量为1.121,3 kWp,电网功率因数为0.867。穿透率超过30%会导致系统功率因数小于允许功率因数标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Buck Converter Output Voltage Control System Using Proportional Integral Differential Method on Solar Cell Battery Charging Hybrid Method for Optimization of Permanent Magnet Synchronous Machine (PMSM) Rotation using FA-ANFIS Increasing Capacity Impact of Power Source Sinergy on Power Flow Evaluation Based on Auxiliary Generator Optimization of Permanent Magnet Synchronous Generator Output Power in Wind Power Plants Using the Gray Wolf Optimization Method Stability Simulation of 150 kV Malang Power Grid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1