Performance of the pipe-base d transmission system in the real field

T. Higuma, N. Kushiro, T. Mukai, M. Katsukura
{"title":"Performance of the pipe-base d transmission system in the real field","authors":"T. Higuma, N. Kushiro, T. Mukai, M. Katsukura","doi":"10.1109/ICCE.2009.5012180","DOIUrl":null,"url":null,"abstract":"We have developed a new pipe-based transmission system, which utilizes a pair of refrigerant pipes of the air conditioner. Field examination of the pipe-based transmission system on the pipeline of existing air-conditioning equipments in a building has been completed. In this paper describes the field test results, such as bit error ratio and physical transmission rates and radiated electric field at the out side of the building. We have confirmed the pipe-based transmission system has practical reliability for the control system through the field test.","PeriodicalId":154986,"journal":{"name":"2009 Digest of Technical Papers International Conference on Consumer Electronics","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Digest of Technical Papers International Conference on Consumer Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCE.2009.5012180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

We have developed a new pipe-based transmission system, which utilizes a pair of refrigerant pipes of the air conditioner. Field examination of the pipe-based transmission system on the pipeline of existing air-conditioning equipments in a building has been completed. In this paper describes the field test results, such as bit error ratio and physical transmission rates and radiated electric field at the out side of the building. We have confirmed the pipe-based transmission system has practical reliability for the control system through the field test.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
管基传动系统在实际应用中的性能
我们开发了一种新的管道传输系统,它利用了空调的一对制冷剂管道。对某建筑现有空调设备的管道进行了管道传输系统的现场检测。本文介绍了误码率、物理传输率和建筑物外辐射电场等现场测试结果。通过现场试验,验证了管式传动系统对控制系统具有实际的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
6.1-1 efficient true motion estimation using integral frame attributes Multi-view renderer for auto-stereoscopic mobile devices Weakly-tethered model using standardized content protection Video generation for high spatio-temporal resolution imaging Camera shaking effects reduction by means of still sequence stabilization and spatio-temporal filtering
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1