Compliance of small-diameter vascular grafts as a determinant of patency

S.W. Mizelle, B. Gupta, V. Kasyanov
{"title":"Compliance of small-diameter vascular grafts as a determinant of patency","authors":"S.W. Mizelle, B. Gupta, V. Kasyanov","doi":"10.1109/SBEC.1995.514422","DOIUrl":null,"url":null,"abstract":"The success of small diameter vascular grafts in determining long term patency is highly limited due to the lack of compliance associated with the structures currently produced. The mismatch in compliance between the graft and the host artery has been noted as the primary cause for graft failure. Currently, there are many methods used to measure compliance, however there still exists a great deal of ambiguity in the measurements obtained by these methods. It is essential that the currently available measurement techniques be reviewed so that a simple standardized method for compliance measurement may be identified and used. The availability of such a method would lead to a significant reduction in the amount of inconsistency currently encountered by researchers when comparing compliance values.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SBEC.1995.514422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The success of small diameter vascular grafts in determining long term patency is highly limited due to the lack of compliance associated with the structures currently produced. The mismatch in compliance between the graft and the host artery has been noted as the primary cause for graft failure. Currently, there are many methods used to measure compliance, however there still exists a great deal of ambiguity in the measurements obtained by these methods. It is essential that the currently available measurement techniques be reviewed so that a simple standardized method for compliance measurement may be identified and used. The availability of such a method would lead to a significant reduction in the amount of inconsistency currently encountered by researchers when comparing compliance values.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
小直径血管移植物的顺应性是通畅的决定因素
由于目前生产的结构缺乏顺应性,小直径血管移植物在确定长期通畅方面的成功受到高度限制。移植物与宿主动脉之间的顺应性不匹配被认为是移植物失败的主要原因。目前,测量顺应性的方法很多,但这些方法得到的测量结果存在很大的模糊性。必须审查目前可用的测量技术,以便确定和使用一种简单的标准化的依从性测量方法。这种方法的可用性将大大减少目前研究人员在比较遵从性值时遇到的不一致的数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
In vivo characterization of hydroxylapatite (HA) coated pyrolytic carbon implants The effects of wetness on coefficient of friction measurement evaluated with three slip testers with varied residence times on selected materials Dynamic three-dimensional in vivo tracking of the abnormal extensor mechanism Resorbable chitosan matrix-a promising biomaterial for the future Sterilization condition of UHMWPE is measured by thermoluminescence technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1