Wyes and wye nots of three-phase distribution transformer connections

R.J. Rusch, M. Good
{"title":"Wyes and wye nots of three-phase distribution transformer connections","authors":"R.J. Rusch, M. Good","doi":"10.1109/REPCON.1989.95535","DOIUrl":null,"url":null,"abstract":"The authors summarize the pros and cons of various three-phase transformer connections. Recommendations are provided regarding the standard types of connections a utility should offer for various service requirements. Consideration is given to warehousing costs, ferroresonance, neutral grounding, core construction, overvoltages, unbalanced loading, zero sequence sources, and through faults. Emphasis is placed on the exchange of information between customer and utility. An application for three-phase service form that can be used to determine service requirements, including voltage, grounded, ungrounded, three-phase load, single-phase load, motor characteristics, and fault current interrupting rating of secondary breakers and switchgear, is provided. It is recommended that a rural electric utility standardize on a limited number of transformer connections to serve three-phase loads. Recommended standard connections include: (1) four-wire service, grounded-wye-grounded-wye; and (2) three-wire service, wye-delta. Suggestions on utility-supplied information such as maximum available three-phase and line-to-ground fault currents are provided, and the operation of ungrounded systems is discussed.<<ETX>>","PeriodicalId":120857,"journal":{"name":"Papers Presented at the 33rd Annual Conference Rural Electric Power Conference","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Papers Presented at the 33rd Annual Conference Rural Electric Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REPCON.1989.95535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

The authors summarize the pros and cons of various three-phase transformer connections. Recommendations are provided regarding the standard types of connections a utility should offer for various service requirements. Consideration is given to warehousing costs, ferroresonance, neutral grounding, core construction, overvoltages, unbalanced loading, zero sequence sources, and through faults. Emphasis is placed on the exchange of information between customer and utility. An application for three-phase service form that can be used to determine service requirements, including voltage, grounded, ungrounded, three-phase load, single-phase load, motor characteristics, and fault current interrupting rating of secondary breakers and switchgear, is provided. It is recommended that a rural electric utility standardize on a limited number of transformer connections to serve three-phase loads. Recommended standard connections include: (1) four-wire service, grounded-wye-grounded-wye; and (2) three-wire service, wye-delta. Suggestions on utility-supplied information such as maximum available three-phase and line-to-ground fault currents are provided, and the operation of ungrounded systems is discussed.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三相配电变压器接线的绕线和绕线
作者总结了各种三相变压器接线的优缺点。针对各种服务需求,提供了公用事业应该提供的标准连接类型的建议。考虑到仓储成本、铁磁谐振、中性点接地、铁芯结构、过电压、不平衡负载、零序源和通过故障。重点放在客户和公用事业单位之间的信息交换上。提供了一份三相服务表格申请表,用于确定服务要求,包括电压、接地、不接地、三相负载、单相负载、电机特性以及二次断路器和开关设备的故障电流中断额定值。建议农村电力公司对有限数量的变压器连接进行标准化,以服务三相负载。推荐的标准连接包括:(1)四线制业务,接地-接地-接地;(2)三线制服务,三角式服务。对电力公司提供的信息,如最大可用三相电流和线路对地故障电流,提出了建议,并讨论了不接地系统的运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Power system disturbance patterns Report on automated capacitor switching (for power factor correction) Distribution transformer loss evaluation: building on REA Bulletin 61-16 Wyes and wye nots of three-phase distribution transformer connections Utility benefits of electronic demand recorder application, translation software, and communication
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1