Research on DFIG Control Strategy under Unbalanced Power Grid Voltage

Zhao Ying, Liu Min
{"title":"Research on DFIG Control Strategy under Unbalanced Power Grid Voltage","authors":"Zhao Ying, Liu Min","doi":"10.1109/ICPICS55264.2022.9873782","DOIUrl":null,"url":null,"abstract":"In the wind power generation system, the Doubly Fed Induction Generator (DFIG) has many advantages and has become a major model of wind energy development and utilization currently. However, the operation control strategy of wind power system based on the ideal grid environment cannot adapt to the requirements of the actual grid conditions. In this paper, firstly, the structure and operation principle of the DFIG system are analyzed, and the mathematical model of DFIG in three-phase static coordinate is established. Then, a PWM converter control simulation method is built on the MATLAB/Simulink platform, and the proportional-integral (PI) vector control strategy is used to carry out simulation experiments. The effectiveness of the proposed control strategy is verified by the final results.","PeriodicalId":257180,"journal":{"name":"2022 IEEE 4th International Conference on Power, Intelligent Computing and Systems (ICPICS)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 4th International Conference on Power, Intelligent Computing and Systems (ICPICS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPICS55264.2022.9873782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the wind power generation system, the Doubly Fed Induction Generator (DFIG) has many advantages and has become a major model of wind energy development and utilization currently. However, the operation control strategy of wind power system based on the ideal grid environment cannot adapt to the requirements of the actual grid conditions. In this paper, firstly, the structure and operation principle of the DFIG system are analyzed, and the mathematical model of DFIG in three-phase static coordinate is established. Then, a PWM converter control simulation method is built on the MATLAB/Simulink platform, and the proportional-integral (PI) vector control strategy is used to carry out simulation experiments. The effectiveness of the proposed control strategy is verified by the final results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电网电压不平衡条件下DFIG控制策略研究
在风力发电系统中,双馈感应发电机(DFIG)具有许多优点,已成为目前风能开发利用的主要模式。然而,基于理想电网环境的风电系统运行控制策略不能适应实际电网条件的要求。本文首先分析了DFIG系统的结构和工作原理,建立了三相静态坐标下DFIG的数学模型。然后,在MATLAB/Simulink平台上建立PWM变换器控制仿真方法,采用比例积分(PI)矢量控制策略进行仿真实验。最后的仿真结果验证了所提控制策略的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Research on small object detection methods based on deep learning Insulation State Assessment of Cable Intermediate Joint based on Fuzzy Comprehensive Evaluation with Variable Weight Development of Automatic Testing Device for Electric Iron Accessories Measures to Solve the High Abnormal Rate of Disconnector Test Values Fault Pattern Recognition Method for DC-DC Power by Using Output Voltage Waveform Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1