Low cost, compact and pulsated constant current microcontroller based nerve locator

H. A. Alzomor, B. K. Ouda
{"title":"Low cost, compact and pulsated constant current microcontroller based nerve locator","authors":"H. A. Alzomor, B. K. Ouda","doi":"10.1109/CIBEC.2012.6473315","DOIUrl":null,"url":null,"abstract":"Regional anesthesia is preferred to global anesthesia when applicable due to its safety, low cost and patient preference. Successful regional anesthesia depends upon precise location of the peripheral nerve or nerve plexus. Locating peripheral nerves is usually done using nerve stimulation which is considered by many to be the current `gold standard'. In order to generate a nerve impulse by electrical means, a threshold stimulus of current must be applied to the nerve “rheobase”. The technique depends on stimulating muscular twitching at a close distance to the nerve without actually touching it. In this paper, a design for μcontroller-based nerve locator is introduced. The current delivered to the nerve is maintained constant in the proposed design for a wide range of load impedances. The device is tested and used to locate the nerves in the limbs of the animal. Moreover, the device tested successfully against IEC safety standards and compared to prior arts. The comparison is based on five characteristics which are waveform, current intensity, impulse duration, maximum load and functionality. Based on that rules the proposed design is able to achieve reasonably high scores that put it on the second place among 22 available nerve stimulators.","PeriodicalId":416740,"journal":{"name":"2012 Cairo International Biomedical Engineering Conference (CIBEC)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Cairo International Biomedical Engineering Conference (CIBEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIBEC.2012.6473315","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Regional anesthesia is preferred to global anesthesia when applicable due to its safety, low cost and patient preference. Successful regional anesthesia depends upon precise location of the peripheral nerve or nerve plexus. Locating peripheral nerves is usually done using nerve stimulation which is considered by many to be the current `gold standard'. In order to generate a nerve impulse by electrical means, a threshold stimulus of current must be applied to the nerve “rheobase”. The technique depends on stimulating muscular twitching at a close distance to the nerve without actually touching it. In this paper, a design for μcontroller-based nerve locator is introduced. The current delivered to the nerve is maintained constant in the proposed design for a wide range of load impedances. The device is tested and used to locate the nerves in the limbs of the animal. Moreover, the device tested successfully against IEC safety standards and compared to prior arts. The comparison is based on five characteristics which are waveform, current intensity, impulse duration, maximum load and functionality. Based on that rules the proposed design is able to achieve reasonably high scores that put it on the second place among 22 available nerve stimulators.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低成本,紧凑的脉动恒流微控制器神经定位器
由于区域麻醉的安全性、低成本和患者的偏好,在适用的情况下,区域麻醉优于全身麻醉。成功的区域麻醉依赖于周围神经或神经丛的精确定位。定位周围神经通常使用神经刺激,这被许多人认为是目前的“黄金标准”。为了通过电学手段产生神经冲动,必须对神经“流变基”施加电流阈值刺激。这项技术依赖于在不接触神经的情况下近距离刺激肌肉抽搐。介绍了一种基于μ控制器的神经定位器的设计。在广泛的负载阻抗范围内,所提出的设计中,传递给神经的电流保持恒定。该装置经过测试并用于定位动物四肢的神经。此外,与现有技术相比,该设备成功地通过了IEC安全标准测试。比较基于波形、电流强度、脉冲持续时间、最大负载和功能这五个特性。基于这些规则,提出的设计能够获得相当高的分数,使其在22种可用的神经刺激器中排名第二。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
3D automated colon segmentation for efficient polyp detection Pectoral muscle identification in mammograms for Computer Aided Diagnosis of breast cancer High performance multi-dimensional (2D/3D) FFT-Shift implementation on Graphics Processing Units (GPUs) A system dynamics based model for medical equipment maintenance procedure planning in developing countries Accurate analysis of cardiac tagged MRI using combined HARP and optical flow tracking
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1