M. Rahiminejad, C. Diduch, M. Stevenson, Liuchen Chang
{"title":"Open-circuit fault diagnosis in 3-phase uncontrolled rectifiers","authors":"M. Rahiminejad, C. Diduch, M. Stevenson, Liuchen Chang","doi":"10.1109/PEDG.2012.6254010","DOIUrl":null,"url":null,"abstract":"This paper proposes a detection method for open-circuit faults in a 3-phase uncontrolled rectifier that forms the input stage of a single-phase current controlled power converter. The rectifier is driven by a 3-phase wind generator with variable amplitude and frequency. The algorithm is based on fault signatures embedded within the output voltage ripple of the rectifier. It is demonstrated that seven different classes of open circuit faults can be detected and isolated.","PeriodicalId":146438,"journal":{"name":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDG.2012.6254010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20
Abstract
This paper proposes a detection method for open-circuit faults in a 3-phase uncontrolled rectifier that forms the input stage of a single-phase current controlled power converter. The rectifier is driven by a 3-phase wind generator with variable amplitude and frequency. The algorithm is based on fault signatures embedded within the output voltage ripple of the rectifier. It is demonstrated that seven different classes of open circuit faults can be detected and isolated.