Partial Discharge Characteristics in Pre-Breakdown Processes of Oil-Pressboard Insulation with Needle-Plate Defect Under AC-DC Combined Voltage

Simeng Li, Qingquan Li, W. Si, Junyan Yao, Yalin Shi, T. Zhang
{"title":"Partial Discharge Characteristics in Pre-Breakdown Processes of Oil-Pressboard Insulation with Needle-Plate Defect Under AC-DC Combined Voltage","authors":"Simeng Li, Qingquan Li, W. Si, Junyan Yao, Yalin Shi, T. Zhang","doi":"10.1109/EIC.2018.8481130","DOIUrl":null,"url":null,"abstract":"The PD characteristics of oil-pressboard insulation with needle-plate defect at AC-DC combined voltage are unstable. In this paper, the time-variation trends of PD characteristics in pre-breakdown process at AC-DC combined voltage are studied via the tests in oil-pressboard insulation with needle-plate defect. The average PD repetition rate and average PD amplitude decrease with the PD developing, and the time-variation trends of them can be divided into fluctuation type and monotone type. The average PD amplitude has no obvious polarity effect, the average PD repetition rate has a polarity effect. In equivalent time-frequency spectrograms, most points move towards arch top with the developing of pre-breakdown processes, where PD equivalent time is 1300–1600 ns and PD equivalent frequency is 7.5-10 MHz. PD equivalent time-frequency spectrograms can be divided into half-arched type and whole-arched type at the end of pre-breakdown processes. The defect in pressboard caused by PD is a possible reason for the appearance of whole-arched time-frequency spectrogram.","PeriodicalId":184139,"journal":{"name":"2018 IEEE Electrical Insulation Conference (EIC)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.2018.8481130","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The PD characteristics of oil-pressboard insulation with needle-plate defect at AC-DC combined voltage are unstable. In this paper, the time-variation trends of PD characteristics in pre-breakdown process at AC-DC combined voltage are studied via the tests in oil-pressboard insulation with needle-plate defect. The average PD repetition rate and average PD amplitude decrease with the PD developing, and the time-variation trends of them can be divided into fluctuation type and monotone type. The average PD amplitude has no obvious polarity effect, the average PD repetition rate has a polarity effect. In equivalent time-frequency spectrograms, most points move towards arch top with the developing of pre-breakdown processes, where PD equivalent time is 1300–1600 ns and PD equivalent frequency is 7.5-10 MHz. PD equivalent time-frequency spectrograms can be divided into half-arched type and whole-arched type at the end of pre-breakdown processes. The defect in pressboard caused by PD is a possible reason for the appearance of whole-arched time-frequency spectrogram.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
交直流复合电压下针板缺陷油压板绝缘预击穿过程局部放电特性
具有针板缺陷的油压板在交直流复合电压下的局部放电特性不稳定。本文通过对具有针板缺陷的油压板绝缘进行试验,研究了交直流复合电压下预击穿过程中局部放电特性的时变趋势。平均PD重复率和平均PD振幅随PD的发展而减小,其时间变化趋势可分为涨落型和单调型。平均PD幅值无明显极性效应,平均PD重复率有极性效应。在等效时频图中,随着预击穿过程的发展,大部分点向拱顶移动,PD等效时间为1300 ~ 1600 ns, PD等效频率为7.5 ~ 10 MHz。在预击穿过程结束时,PD等效时频谱图可分为半拱形型和全拱形型。PD引起的压板缺陷可能是产生全拱时频图的原因之一。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental Research on Flashover Characteristics of Insulator with N2 Dissolved Gas Analysis (DGA) of Arc Discharge Fault in Transformer Insulation Oils (Ester and Mineral Oils) Nonparametric Kernel Density Estimation Model of Transformer Health Based on Dissolved Gases in Oil Experimental validation of a moisture sensor for cellulosic insulation of power transformers Development Process of Vibration Sparking Erosion on Stator Bars
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1