Fire simulation tests of mineral oil and natural esters transformers

M. Mazzaro, D. De Bartolomeo, M. Pompili, L. Calcara, S. Sangiovanni, F. Scatiggio, A. Valant, M. Rebolini, A. Ledda, E. Bemporad, S. Berardi, F. Mauri, M. Salvadori, A. Sturchio, M. Falconi
{"title":"Fire simulation tests of mineral oil and natural esters transformers","authors":"M. Mazzaro, D. De Bartolomeo, M. Pompili, L. Calcara, S. Sangiovanni, F. Scatiggio, A. Valant, M. Rebolini, A. Ledda, E. Bemporad, S. Berardi, F. Mauri, M. Salvadori, A. Sturchio, M. Falconi","doi":"10.1109/ICDL.2019.8796788","DOIUrl":null,"url":null,"abstract":"This paper describes the work carried out by the Italian Institutional Working Group on Natural Esters; this Group has been promoted by the University of Roma ”La Sapienza”, the National Firefighters Authority, the National Institute for Insurance against Accidents at Work (INAIL) and the Department for Geological Survey of Italy (ISPRA) with the objective of further validating the real possibility of risk mitigation for humans and environment through a more widespread use of a new generation of transformers insulated with natural ester liquids. A useful contribution to the activities of the Italian Institutional Group on Natural Esters has been also given by the participation of some of the major players in the electrical sector, such as: Italian TSO, main Distributors, Natural Ester producers and transformer manufacturers. The development of this Italian Group at international level has been the set-up of the CIGRE WG D1.68 “Natural and synthetic esters - Evaluation of the performance under fire and the impact on environment”, which is actually preparing a report on this subject. The present paper reports the main results of experimental comparative fire simulations of both mineral oil and natural esters distribution transformers.","PeriodicalId":102217,"journal":{"name":"2019 IEEE 20th International Conference on Dielectric Liquids (ICDL)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 20th International Conference on Dielectric Liquids (ICDL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDL.2019.8796788","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper describes the work carried out by the Italian Institutional Working Group on Natural Esters; this Group has been promoted by the University of Roma ”La Sapienza”, the National Firefighters Authority, the National Institute for Insurance against Accidents at Work (INAIL) and the Department for Geological Survey of Italy (ISPRA) with the objective of further validating the real possibility of risk mitigation for humans and environment through a more widespread use of a new generation of transformers insulated with natural ester liquids. A useful contribution to the activities of the Italian Institutional Group on Natural Esters has been also given by the participation of some of the major players in the electrical sector, such as: Italian TSO, main Distributors, Natural Ester producers and transformer manufacturers. The development of this Italian Group at international level has been the set-up of the CIGRE WG D1.68 “Natural and synthetic esters - Evaluation of the performance under fire and the impact on environment”, which is actually preparing a report on this subject. The present paper reports the main results of experimental comparative fire simulations of both mineral oil and natural esters distribution transformers.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
矿物油和天然酯变压器的火灾模拟试验
本文介绍了意大利天然酯机构工作组所开展的工作;该小组由罗马"拉萨皮恩扎"大学、国家消防管理局、国家工伤事故保险研究所和意大利地质调查局推动,目的是进一步验证通过更广泛地使用用天然酯液体绝缘的新一代变压器,为人类和环境减轻风险的真正可能性。电力部门的一些主要参与者的参与也对意大利天然酯机构小组的活动作出了有益的贡献,例如:意大利TSO、主要分销商、天然酯生产商和变压器制造商。这个意大利集团在国际层面的发展已经建立了CIGRE WG D1.68“天然和合成酯-评估火灾下的性能和对环境的影响”,它实际上正在准备一份关于这个主题的报告。本文报道了矿物油和天然酯类配电变压器火灾模拟的主要实验对比结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
SF6 Gas Replacement in Pulsed High Voltage Coaxial Cables Electron Self-Trapping in Vortex Rings in Superfluid Helium Numerical Study of the Thermal Excitation Applied to a Dielectric Liquid Film Assessing the Production and Loss of Electrons from Conduction Currents in Mineral Oil The conformity of DGA interpretation techniques: Experience from transformer 132 units
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1