{"title":"Lightning transients on branched distribution lines considering frequency-dependent ground parameters","authors":"A. De Conti, R. Alípio","doi":"10.1109/ICLP.2016.7791375","DOIUrl":null,"url":null,"abstract":"This paper investigates the influence of considering frequency-dependent ground parameters in the calculation of lightning transients on a two-phase distribution line including the presence of branches. The analysis is focused on propagation effects along the line. It is shown that the influence of frequency-dependent ground parameters is only remarkable if a poorly-conducting ground is considered. It is also shown that the presence of line branches is likely to reduce the relative importance of considering the frequency variation of the ground parameters in the calculation of lightning transients.","PeriodicalId":373744,"journal":{"name":"2016 33rd International Conference on Lightning Protection (ICLP)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 33rd International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2016.7791375","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper investigates the influence of considering frequency-dependent ground parameters in the calculation of lightning transients on a two-phase distribution line including the presence of branches. The analysis is focused on propagation effects along the line. It is shown that the influence of frequency-dependent ground parameters is only remarkable if a poorly-conducting ground is considered. It is also shown that the presence of line branches is likely to reduce the relative importance of considering the frequency variation of the ground parameters in the calculation of lightning transients.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
考虑频率相关接地参数的分支配电线路雷电瞬变
本文研究了考虑频率相关的接地参数对含支路的两相配电线路雷电瞬变计算的影响。分析的重点是沿线路的传播效应。结果表明,频率相关接地参数的影响只有在考虑导电差的情况下才显著。研究还表明,线路分支的存在可能会降低计算雷电瞬变时考虑地参数频率变化的相对重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental and theoretical evaluation of aluminium deflection due to lightning strikes Degradation characteristics on MOV of surge arrester used for 6.6kV power distribution line Lightning protection of a temporary structure in open area Lightning performance of EHV and UHV overhead transmission Lines in China southern power grid Research of influence pattern of lightning current on impulse characteristic of ground device for pole and tower
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1