{"title":"Using of autodyne transceiver modules on Gunn diodes for determination of turbomachine blades deformations","authors":"A. Danilin, S. Votoropin, A. G. Tcherniavski","doi":"10.1109/CRMICO.2001.961705","DOIUrl":null,"url":null,"abstract":"The levels of mechanical deformations of dynamically loaded blades in modern turbomachines in great extent define durability and reliability of gas-turbine engines. The report materials present the radar method and device for control of dynamic blades characteristics of gas-turbine engines (GTE). Primary converters with autodyne transceiver modules based on Gunn diodes are used in the discrete-phase method (DPM) equipment. The block diagram of the measuring setup and results of experimental studies are given.","PeriodicalId":197471,"journal":{"name":"11th International Conference 'Microwave and Telecommunication Technology'. Conference Proceedings (IEEE Cat. No.01EX487)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2001-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"11th International Conference 'Microwave and Telecommunication Technology'. Conference Proceedings (IEEE Cat. No.01EX487)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CRMICO.2001.961705","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
The levels of mechanical deformations of dynamically loaded blades in modern turbomachines in great extent define durability and reliability of gas-turbine engines. The report materials present the radar method and device for control of dynamic blades characteristics of gas-turbine engines (GTE). Primary converters with autodyne transceiver modules based on Gunn diodes are used in the discrete-phase method (DPM) equipment. The block diagram of the measuring setup and results of experimental studies are given.