Research on transient electric field distribution of converter transformer valve side winding under polarity reversal

Zhang Liang-xian, Zhang Qi-min, Chen Mo-sheng, Pen Zong-ren
{"title":"Research on transient electric field distribution of converter transformer valve side winding under polarity reversal","authors":"Zhang Liang-xian, Zhang Qi-min, Chen Mo-sheng, Pen Zong-ren","doi":"10.1109/CEIDP.2013.6747085","DOIUrl":null,"url":null,"abstract":"Converter transformer is the most important equipment in DC transmission system. Polarity reversal is a special working condition of converter transformer in service, and the polarity reversal test is also generally regarded as the most important experiment for converter transformer. In the calculation of the polarity reversal field, the permittivity and conductivity of the each dielectric material should be given. The insulation materials of converter transformer are oil and pressboard. The resistivity of pressboard is anisotropic, there is a great difference value between the directions of through and along the paper layer. Different polarity reversal durations have different experiment results during polarity reversal test process. In this paper, the electric field distribution of converter transformer valve side winding in a practical ±800 converter transformer under polarity reversal test voltage was calculated with field-circuit coupling method. The anisotropism of paperboard resistivity was taken into account during the calculation process. In order to analyse the influence of polarity reversal duration to the distribution of electric field, several different polarity reversal durations were set to contrast. The results of this paper could provide references for the research and design of converter transformer.","PeriodicalId":393969,"journal":{"name":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2013.6747085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

Converter transformer is the most important equipment in DC transmission system. Polarity reversal is a special working condition of converter transformer in service, and the polarity reversal test is also generally regarded as the most important experiment for converter transformer. In the calculation of the polarity reversal field, the permittivity and conductivity of the each dielectric material should be given. The insulation materials of converter transformer are oil and pressboard. The resistivity of pressboard is anisotropic, there is a great difference value between the directions of through and along the paper layer. Different polarity reversal durations have different experiment results during polarity reversal test process. In this paper, the electric field distribution of converter transformer valve side winding in a practical ±800 converter transformer under polarity reversal test voltage was calculated with field-circuit coupling method. The anisotropism of paperboard resistivity was taken into account during the calculation process. In order to analyse the influence of polarity reversal duration to the distribution of electric field, several different polarity reversal durations were set to contrast. The results of this paper could provide references for the research and design of converter transformer.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
极性反转下换流变压器阀侧绕组暂态电场分布研究
换流变压器是直流输电系统中最重要的设备。极性反转是现役换流变压器的一种特殊工况,极性反转试验也被普遍认为是换流变压器最重要的试验。在计算极性反转场时,应给出各介质材料的介电常数和电导率。换流变压器的绝缘材料是油和压板。纸板的电阻率具有各向异性,穿透和沿纸层方向的电阻率值相差很大。在极性反转测试过程中,不同的极性反转持续时间有不同的实验结果。本文采用场路耦合法计算了实际±800换流变压器在极性反转试验电压下换流变压器阀侧绕组的电场分布。在计算过程中考虑了纸板电阻率的各向异性。为了分析极性反转持续时间对电场分布的影响,设置了几种不同的极性反转持续时间进行对比。本文的研究结果可为换流变压器的研究和设计提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measurements of THz absorption peaks in photo-degraded polyethylene and their assignment by quantum chemical calculations Charge transport characteristics in epoxy resin at high temperatures based on electrode polarization analysis Experimental study on the dielectric properties of a liquid crystal polymer Influence of nano-titanium dioxide (TiO2) on electrical tree characteristics in silicone rubber based nanocomposite Phenomenon of secondary reverse streamer in an ester transformer liquid under lightning impulse voltage
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1