New proposal of correction factors for dc voltages

P. Calva, V. del Moral, M.G. Marquez, G.P. Cabrera
{"title":"New proposal of correction factors for dc voltages","authors":"P. Calva, V. del Moral, M.G. Marquez, G.P. Cabrera","doi":"10.1109/CEIDP.2003.1254891","DOIUrl":null,"url":null,"abstract":"The IEC-60-1989 and IEEE Std. 4-1995 procedures for dc voltages are not suitable for high altitudes. The assumption that the streamer propagation field varies linearly with the relative air density does not apply to high-altitude dc breakdown. Recently it has been published some work related to the positive polarity, in this paper, finally, considering both positive and negative polarities a new proposal of correction factors for dc voltages is presented. It has been concluded that the effect of air density and humidity can be accounted for independently, that in positive polarity it is necessary to correct both for relative air density and for humidity, but in negative polarity only by relative air density, furthermore, a gap factor for different arrangements of electrodes is introduced.","PeriodicalId":306575,"journal":{"name":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2003.1254891","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

The IEC-60-1989 and IEEE Std. 4-1995 procedures for dc voltages are not suitable for high altitudes. The assumption that the streamer propagation field varies linearly with the relative air density does not apply to high-altitude dc breakdown. Recently it has been published some work related to the positive polarity, in this paper, finally, considering both positive and negative polarities a new proposal of correction factors for dc voltages is presented. It has been concluded that the effect of air density and humidity can be accounted for independently, that in positive polarity it is necessary to correct both for relative air density and for humidity, but in negative polarity only by relative air density, furthermore, a gap factor for different arrangements of electrodes is introduced.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
直流电压校正系数的新建议
IEC-60-1989和IEEE Std. 4-1995直流电压规程不适用于高海拔地区。流光传播场随相对空气密度线性变化的假设不适用于高空直流击穿。近年来已发表了一些与正极性有关的工作,本文最后在考虑正极性和负极性的情况下,提出了直流电压校正系数的新建议。得出的结论是,空气密度和湿度的影响可以独立解释,在正极性中需要对相对空气密度和湿度进行校正,但在负极性中只需要通过相对空气密度进行校正,此外,引入了不同电极排列的间隙因子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The effect of temperature and the mutual influence between two cavities of on the appearance of partial discharges in gaseous cavities contained in the insulator of high voltage Breakdown strength at the interface between epoxy resin and silicone rubber Surface change of polyamide nanocomposite caused by partial discharges Surface finish effects on partial discharge with embedded electrodes Roles of cumyl alcohol and crosslinked structure in homo-charge trapping in crosslinked polyethylene
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1