{"title":"Testing of UCA based microprocessor based protective relays","authors":"B. Vandiver","doi":"10.1109/PESS.2002.1043236","DOIUrl":null,"url":null,"abstract":"UCA based protective relays use high-speed peer-to-peer communications to Implement distributed protection schemes or to replace hard wired Interface between relays with GOOSE messages defined by UCA 2.0 and JEC 61850. The paper presents the requirements for testing of such devices, including the specifics of simulation of the substation environment and monitoring of the performance of the relay under test.","PeriodicalId":117177,"journal":{"name":"IEEE Power Engineering Society Summer Meeting,","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Engineering Society Summer Meeting,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESS.2002.1043236","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

UCA based protective relays use high-speed peer-to-peer communications to Implement distributed protection schemes or to replace hard wired Interface between relays with GOOSE messages defined by UCA 2.0 and JEC 61850. The paper presents the requirements for testing of such devices, including the specifics of simulation of the substation environment and monitoring of the performance of the relay under test.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于UCA的微处理器保护继电器的测试
基于UCA的保护继电器使用高速点对点通信实现分布式保护方案,或用UCA 2.0和JEC 61850定义的GOOSE消息取代继电器之间的硬连线接口。本文提出了此类设备的测试要求,包括变电站环境的模拟和被测继电器性能的监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
New algorithm to phase selection based on wavelet transforms A parameter identification technique for metal-oxide surge arrester models Dynamic security enhancement in power-market systems Evaluation of currents and charges in low-voltage surge arresters due to lightning strikes Local area spatial load forecasting at NSTAR
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1