A Study of Power Outage Reduction Due to Lightning by Using the Different Dielectric Strength of Supporting Points of Distribution Lines

H. Honda, Takafumi Kuno, Yoshiyasu Koga
{"title":"A Study of Power Outage Reduction Due to Lightning by Using the Different Dielectric Strength of Supporting Points of Distribution Lines","authors":"H. Honda, Takafumi Kuno, Yoshiyasu Koga","doi":"10.1109/APL57308.2023.10181334","DOIUrl":null,"url":null,"abstract":"Lightning has been the leading cause of power outage, therefore, there is a need for further reduction of outage caused by lightning. In this paper, authors are considering the application of resin arms, which can be a new menu for countermeasures of outage caused lightning. Since the resin arm has a different path length of ground fault path of the three-phase distribution wire, by appropriately arranging the phases that are prone to ground faults by changing the arrangement, it can be a rational countermeasure against power outage caused by lightning that allows up to one phase ground faults. Authors measured the creepage breakdown voltage of the prototype resin plate and verified the reduction of power outage caused by lightning by analysis.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 12th Asia-Pacific International Conference on Lightning (APL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APL57308.2023.10181334","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Lightning has been the leading cause of power outage, therefore, there is a need for further reduction of outage caused by lightning. In this paper, authors are considering the application of resin arms, which can be a new menu for countermeasures of outage caused lightning. Since the resin arm has a different path length of ground fault path of the three-phase distribution wire, by appropriately arranging the phases that are prone to ground faults by changing the arrangement, it can be a rational countermeasure against power outage caused by lightning that allows up to one phase ground faults. Authors measured the creepage breakdown voltage of the prototype resin plate and verified the reduction of power outage caused by lightning by analysis.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用配电线路支撑点不同介电强度减少雷电致停电的研究
雷电是造成电力中断的主要原因,因此,有必要进一步减少雷电造成的停电。本文正在考虑树脂臂的应用,它可以作为停电雷击的一种新手段。由于树脂臂与三相配电线接地故障路径的路径长度不同,通过改变排列方式,适当地安排易发生接地故障的相,可以合理地应对雷击造成的停电,最多可发生一相接地故障。测量了原型树脂板的漏电击穿电压,并通过分析验证了其减少了雷电引起的停电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of cost-effective lightning protection measures for underprivileged communities Preliminary Results of Corona Discharge Current Measurements in the Early Formation of Lightning on Tower Performance of Bentonite and Peat Moss Mixtures as Grounding Enhancement Materials Thunderstorm Prediction Model Using SMOTE Sampling and Machine Learning Approach A Year of Global Lightning Deaths and Injuries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1