Jong Won Chung, Sang Won Park, Seung-Beom Han, Jong-Seon Park, H. Kim, W. Lee
{"title":"Cementless Total Hip Arthroplasty for Osteonecrosis of the Femoral Head - A Follow-up Study for 10+ Years -","authors":"Jong Won Chung, Sang Won Park, Seung-Beom Han, Jong-Seon Park, H. Kim, W. Lee","doi":"10.5371/JKHS.2010.22.2.129","DOIUrl":null,"url":null,"abstract":"Purpose: The aim of this study was to assess the outcome of cementless total hip arthroplasty (THA) in cases of osteonecrosis of the femoral head. Materials and Methods: We studied long-term outcomes for 54 patients (72 hips). Mean duration of follow-up was 13.5 years. Clinical outcomes were evaluated by the Harris Hip Score. Radiographic evaluation from the preoperative and follow-up periods included assessment of the fixation of the femoral and acetabular components, polyethylene wear, osteolysis, and radiolucent line. Results: The mean Harris Hip Score improved from a preoperative value of 51.9 points to 89.4 at final follow-up. Regarding the femoral components, there was radiographic evidence of stable bony ingrowth in 69 hips, stable fibrous ingrowth in 2 hips and unstable fixation in 1 hip. There was a radiolucent line of less than 1 mm in 7 hips, and femoral osteolysis in 27 hips. Regarding the acetabular components, there was radiographic evidence of stable fixation in 68 hips, unstable fixation in 4 hips, and osteolysis in 39 hips. There was a significant correlation between (i) failure of components and (ii) femoral osteolysis, acetabular osteolysis, polyethylene thickness, linear wear rate per year, or total linear wear. Conclusion: The findings of this study show favorable long term results, both clinical and radiographic, using cementless total hip replacement arthroplasties. However, the revision rates for the Harris-Galante acetabular components were high. Wear of the load? weight? bearing surface continues to limit the long-term success rate of THA, and improved design of the acetabular components should be considered.","PeriodicalId":410202,"journal":{"name":"The Journal of the Korean Hip Society","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the Korean Hip Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5371/JKHS.2010.22.2.129","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose: The aim of this study was to assess the outcome of cementless total hip arthroplasty (THA) in cases of osteonecrosis of the femoral head. Materials and Methods: We studied long-term outcomes for 54 patients (72 hips). Mean duration of follow-up was 13.5 years. Clinical outcomes were evaluated by the Harris Hip Score. Radiographic evaluation from the preoperative and follow-up periods included assessment of the fixation of the femoral and acetabular components, polyethylene wear, osteolysis, and radiolucent line. Results: The mean Harris Hip Score improved from a preoperative value of 51.9 points to 89.4 at final follow-up. Regarding the femoral components, there was radiographic evidence of stable bony ingrowth in 69 hips, stable fibrous ingrowth in 2 hips and unstable fixation in 1 hip. There was a radiolucent line of less than 1 mm in 7 hips, and femoral osteolysis in 27 hips. Regarding the acetabular components, there was radiographic evidence of stable fixation in 68 hips, unstable fixation in 4 hips, and osteolysis in 39 hips. There was a significant correlation between (i) failure of components and (ii) femoral osteolysis, acetabular osteolysis, polyethylene thickness, linear wear rate per year, or total linear wear. Conclusion: The findings of this study show favorable long term results, both clinical and radiographic, using cementless total hip replacement arthroplasties. However, the revision rates for the Harris-Galante acetabular components were high. Wear of the load? weight? bearing surface continues to limit the long-term success rate of THA, and improved design of the acetabular components should be considered.