Cementless Total Hip Arthroplasty for Osteonecrosis of the Femoral Head - A Follow-up Study for 10+ Years -

Jong Won Chung, Sang Won Park, Seung-Beom Han, Jong-Seon Park, H. Kim, W. Lee
{"title":"Cementless Total Hip Arthroplasty for Osteonecrosis of the Femoral Head - A Follow-up Study for 10+ Years -","authors":"Jong Won Chung, Sang Won Park, Seung-Beom Han, Jong-Seon Park, H. Kim, W. Lee","doi":"10.5371/JKHS.2010.22.2.129","DOIUrl":null,"url":null,"abstract":"Purpose: The aim of this study was to assess the outcome of cementless total hip arthroplasty (THA) in cases of osteonecrosis of the femoral head. Materials and Methods: We studied long-term outcomes for 54 patients (72 hips). Mean duration of follow-up was 13.5 years. Clinical outcomes were evaluated by the Harris Hip Score. Radiographic evaluation from the preoperative and follow-up periods included assessment of the fixation of the femoral and acetabular components, polyethylene wear, osteolysis, and radiolucent line. Results: The mean Harris Hip Score improved from a preoperative value of 51.9 points to 89.4 at final follow-up. Regarding the femoral components, there was radiographic evidence of stable bony ingrowth in 69 hips, stable fibrous ingrowth in 2 hips and unstable fixation in 1 hip. There was a radiolucent line of less than 1 mm in 7 hips, and femoral osteolysis in 27 hips. Regarding the acetabular components, there was radiographic evidence of stable fixation in 68 hips, unstable fixation in 4 hips, and osteolysis in 39 hips. There was a significant correlation between (i) failure of components and (ii) femoral osteolysis, acetabular osteolysis, polyethylene thickness, linear wear rate per year, or total linear wear. Conclusion: The findings of this study show favorable long term results, both clinical and radiographic, using cementless total hip replacement arthroplasties. However, the revision rates for the Harris-Galante acetabular components were high. Wear of the load? weight? bearing surface continues to limit the long-term success rate of THA, and improved design of the acetabular components should be considered.","PeriodicalId":410202,"journal":{"name":"The Journal of the Korean Hip Society","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the Korean Hip Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5371/JKHS.2010.22.2.129","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: The aim of this study was to assess the outcome of cementless total hip arthroplasty (THA) in cases of osteonecrosis of the femoral head. Materials and Methods: We studied long-term outcomes for 54 patients (72 hips). Mean duration of follow-up was 13.5 years. Clinical outcomes were evaluated by the Harris Hip Score. Radiographic evaluation from the preoperative and follow-up periods included assessment of the fixation of the femoral and acetabular components, polyethylene wear, osteolysis, and radiolucent line. Results: The mean Harris Hip Score improved from a preoperative value of 51.9 points to 89.4 at final follow-up. Regarding the femoral components, there was radiographic evidence of stable bony ingrowth in 69 hips, stable fibrous ingrowth in 2 hips and unstable fixation in 1 hip. There was a radiolucent line of less than 1 mm in 7 hips, and femoral osteolysis in 27 hips. Regarding the acetabular components, there was radiographic evidence of stable fixation in 68 hips, unstable fixation in 4 hips, and osteolysis in 39 hips. There was a significant correlation between (i) failure of components and (ii) femoral osteolysis, acetabular osteolysis, polyethylene thickness, linear wear rate per year, or total linear wear. Conclusion: The findings of this study show favorable long term results, both clinical and radiographic, using cementless total hip replacement arthroplasties. However, the revision rates for the Harris-Galante acetabular components were high. Wear of the load? weight? bearing surface continues to limit the long-term success rate of THA, and improved design of the acetabular components should be considered.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
无骨水泥全髋关节置换术治疗股骨头骨坏死- 10年以上随访研究
目的:本研究的目的是评估无骨水泥全髋关节置换术(THA)治疗股骨头骨坏死的效果。材料和方法:我们研究了54例患者(72髋)的长期预后。平均随访时间为13.5年。临床结果通过Harris髋关节评分进行评估。术前和随访期间的影像学评估包括评估股骨和髋臼部件的固定情况、聚乙烯磨损、骨溶解和放射线。结果:Harris髋关节平均评分从术前51.9分提高到最终随访时的89.4分。关于股骨假体,x线片显示69例髋关节骨长入稳定,2例髋关节纤维长入稳定,1例髋关节内固定不稳定。7例髋部出现小于1mm的透光线,27例髋部出现股骨骨溶解。关于髋臼假体,有影像学证据显示68髋稳定固定,4髋不稳定固定,39髋骨溶解。(i)部件失效与(ii)股骨骨溶解、髋臼骨溶解、聚乙烯厚度、每年线性磨损率或总线性磨损之间存在显著相关性。结论:本研究结果显示无骨水泥全髋关节置换术在临床和影像学上均有良好的长期效果。然而,Harris-Galante髋臼假体的翻修率很高。负载的磨损?体重吗?承载面继续限制THA的长期成功率,应考虑改进髋臼假体的设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Aim of Medicine Comparative Analysis of Two Cementless Stems in Total Hip Arthroplasties in Patients with Osteonecrosis of Femoral Head - Summit® Stem and Bencox® Stem - Repeated Ceramic Head Fracture after Ceramic-on-ceramic Total Hip Arthroplasty Cementless Total Hip Arthroplasty in Dysplastic Hips Hip Arthroplasty Using Collarless Polished Tapered Stem -Minimum 2 Years Follow-up Results-
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1