Towards a 30 kW/liter, Three-Phase Unity Power Factor Rectifier

S. Round, P. Karutz, M. Heldwein, J. Kolar
{"title":"Towards a 30 kW/liter, Three-Phase Unity Power Factor Rectifier","authors":"S. Round, P. Karutz, M. Heldwein, J. Kolar","doi":"10.1541/IEEJIAS.128.481","DOIUrl":null,"url":null,"abstract":"In this paper, a forced air-cooled, 400 kHz, 10 kW Vienna rectifier with a power density of 8.5 kW/liter is presented. To further improve the power density, the switching frequency is increased to reduce the EMI filter volume. A design for an 18.5 kW/liter, 2.5 MHz rectifier is proposed. By using today's technology, it is calculated that the maximum power density for a forced air-cooled and water-cooled rectifier is 20.8 kW/liter and 24 kW/liter respectively. To achieve 30 kW/liter, improvements must be made in passive component material properties, reducing semiconductor losses and improving the cooling system.","PeriodicalId":325362,"journal":{"name":"2007 Power Conversion Conference - Nagoya","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"61","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Power Conversion Conference - Nagoya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1541/IEEJIAS.128.481","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 61

Abstract

In this paper, a forced air-cooled, 400 kHz, 10 kW Vienna rectifier with a power density of 8.5 kW/liter is presented. To further improve the power density, the switching frequency is increased to reduce the EMI filter volume. A design for an 18.5 kW/liter, 2.5 MHz rectifier is proposed. By using today's technology, it is calculated that the maximum power density for a forced air-cooled and water-cooled rectifier is 20.8 kW/liter and 24 kW/liter respectively. To achieve 30 kW/liter, improvements must be made in passive component material properties, reducing semiconductor losses and improving the cooling system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
迈向30千瓦/升三相统一功率因数整流器
本文介绍了一种功率密度为8.5 kW/l的强制风冷、400 kHz、10 kW维也纳整流器。为了进一步提高功率密度,提高开关频率以减小EMI滤波器体积。提出了一种18.5 kW/l、2.5 MHz整流器的设计方案。通过使用当今的技术,可以计算出强制风冷整流器和水冷整流器的最大功率密度分别为20.8 kW/l和24 kW/l。为了达到30千瓦/升,必须改进无源元件材料性能,减少半导体损耗并改进冷却系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Virtual-Flux Direct Power Control for Mains Connected Three-Level NPC Inverter Systems Three-Level ZVZCS and ZVS Half-Bridge Converters: A Comparative Evaluation Trend of high voltage harness technology that supports Hybrid-Electric-Vehicles A Novel Control Strategy for Matrix Converters in Over-modulation Range. Line Loss Minimum Control of Loop Distribution Systems Using UPFC
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1