Retention force of all-zirconia, all-polyetheretherketone, and zirconia-polyetheretherketone telescopic attachments for implant-retained overdentures: In vitro comparative study

Radwa Kamal Emera, Mohamed Elgamal, Gilan Y Altonbary
{"title":"Retention force of all-zirconia, all-polyetheretherketone, and zirconia-polyetheretherketone telescopic attachments for implant-retained overdentures: In vitro comparative study","authors":"Radwa Kamal Emera, Mohamed Elgamal, Gilan Y Altonbary","doi":"10.4103/jdi.jdi_4_20","DOIUrl":null,"url":null,"abstract":"Aim: The aim was to evaluate and compare retention forces of all-zirconia (ZrO2), all-polyetheretherketone (PEEK), and ZrO2-PEEK Computer-Aided-Designing computer-Aided -Manufacturing (CAD-CAM) telescopic attachments for two implant-retained mandibular overdentures. Materials and Methods: Fifteen identical acrylic resin models of the edentulous mandibular arch without alveolar undercuts were fabricated. Two implants were inserted in the canine region of each model. According to the material of telescopic attachment, models were divided into three groups: all ZrO2 (ZZ): primary and secondary crowns were made of ZrO2, all PEEK (PP): primary and secondary crowns were made of PEEK, and ZrO2-PEEK (ZP): primary crowns were made of ZrO2 and secondary ones were made of PEEK. Identical experimental overdentures were constructed for all models. For measuring the retention force, a universal testing machine was used to apply a pull-off test in presence of artificial saliva between the crowns. The achieved maximum values of retention force were recorded at the beginning of the study (initial retention) and after 540 cycles of insertion and removal simulating 6 months of the clinical service (final retention). Results were statistically analyzed, analysis of variance (P < 0.05). Results: ZP group reported the highest initial force values for all groups. The final retention values of PP and ZP groups were significantly decreased than initial values, while the insignificant loss of retention was observed with ZZ group (P = 0.06). Independent samples test showed a significant difference in both initial and final retentions between each two groups. Conclusion: Within the limitations of this study, ZrO2 is more preferred as a secondary telescopic crown against a primary ZrO2 one. Despite the loss of retention by time, PEEK can still be used as a secondary telescopic crown against ZrO2 or PEEK primary crowns regarding the acceptable initial and final retention values.","PeriodicalId":212982,"journal":{"name":"Journal of Dental Implants","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jdi.jdi_4_20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Aim: The aim was to evaluate and compare retention forces of all-zirconia (ZrO2), all-polyetheretherketone (PEEK), and ZrO2-PEEK Computer-Aided-Designing computer-Aided -Manufacturing (CAD-CAM) telescopic attachments for two implant-retained mandibular overdentures. Materials and Methods: Fifteen identical acrylic resin models of the edentulous mandibular arch without alveolar undercuts were fabricated. Two implants were inserted in the canine region of each model. According to the material of telescopic attachment, models were divided into three groups: all ZrO2 (ZZ): primary and secondary crowns were made of ZrO2, all PEEK (PP): primary and secondary crowns were made of PEEK, and ZrO2-PEEK (ZP): primary crowns were made of ZrO2 and secondary ones were made of PEEK. Identical experimental overdentures were constructed for all models. For measuring the retention force, a universal testing machine was used to apply a pull-off test in presence of artificial saliva between the crowns. The achieved maximum values of retention force were recorded at the beginning of the study (initial retention) and after 540 cycles of insertion and removal simulating 6 months of the clinical service (final retention). Results were statistically analyzed, analysis of variance (P < 0.05). Results: ZP group reported the highest initial force values for all groups. The final retention values of PP and ZP groups were significantly decreased than initial values, while the insignificant loss of retention was observed with ZZ group (P = 0.06). Independent samples test showed a significant difference in both initial and final retentions between each two groups. Conclusion: Within the limitations of this study, ZrO2 is more preferred as a secondary telescopic crown against a primary ZrO2 one. Despite the loss of retention by time, PEEK can still be used as a secondary telescopic crown against ZrO2 or PEEK primary crowns regarding the acceptable initial and final retention values.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全氧化锆、全聚醚酮、氧化锆-聚醚酮套筒附着体在种植覆盖义齿中的固位力:体外比较研究
目的:评价和比较全氧化锆(ZrO2)、全聚醚醚酮(PEEK)和ZrO2-PEEK计算机辅助设计制造(CAD-CAM)伸缩附着体在两种种植下颌覆盖义齿中的固位力。材料与方法:制作15个完全相同的无牙槽下弓丙烯酸树脂模型。在每个模型的犬区植入两颗植入物。根据伸缩附件的材料,将模型分为三组:全ZrO2 (ZZ):主要和次要冠由ZrO2制成,全PEEK (PP):主要和次要冠由PEEK制成,ZrO2-PEEK (ZP):主要冠由ZrO2制成,次要冠由PEEK制成。所有模型均构建相同的实验覆盖义齿。为了测量固位力,使用万能试验机在牙冠之间存在人工唾液的情况下进行拉脱试验。在研究开始时(初始固位)和在模拟临床服务6个月的540次插入和取出后(最终固位)记录所达到的最大固位力值。结果进行统计学分析,方差分析(P < 0.05)。结果:ZP组初始力值最高。PP组和ZP组的最终滞留值较初始值显著降低,而ZZ组的滞留值损失不显著(P = 0.06)。独立样本测试显示,两组的初始和最终保留率均有显著差异。结论:在本研究的限制范围内,ZrO2作为二次伸缩冠比ZrO2首选。尽管随着时间的推移,PEEK的固位会减少,但在可接受的初始和最终固位值方面,PEEK仍然可以用作ZrO2或PEEK主冠的二次伸缩冠。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Piezo osteotomy with all-on-4 implants to enable a full-arch rehabilitation A comparative evaluation of bite pressure between single implant prosthesis and natural teeth: An in-vivo study Two implant-retained mandibular overdenture using locator attachment – A clinical report Systemic medications and implant success: Is there a link? Part three: The effects of antiresorptive and anti-angiogenic agents on the outcome of implant therapy Gender-based predilection for the microbial load of Aggregatibacter actinomycetemcomitans present in anterior versus posterior implant sites: A preliminary observational study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1