Kaimiao Liu, Peng Li, Shi SongZhang, Xiaojun Wang, Bin Yang, Gang Li, X. Shi, Xiao Juan Zhu
{"title":"Investigate of Electrical Performance of CuCr30 Manufactured by Three Different Ways","authors":"Kaimiao Liu, Peng Li, Shi SongZhang, Xiaojun Wang, Bin Yang, Gang Li, X. Shi, Xiao Juan Zhu","doi":"10.1109/ICEPE-ST.2019.8928675","DOIUrl":null,"url":null,"abstract":"This paper compared the interruption , anti-welding and voltage withstand abilities of CuCr30 manufactured by three different ways, in which the influence of different manufactured ways on the electrical performance of vacuum interrupter (VI) was investigated. These results can worked as a reference for the selection of CuCr contacts used in the VI. The tested results compared the electrical performance under various CuCr30 manufactured by three different ways. Firstly, the results indicate that for arc-melted(VAR), powder metallurgy(PM) and vacuum casting(VIM) contacts power frequency withstand ability of those contacts can up to 65.9kV to 55.45kV 56.1kV respective.Secondly interruption times of those contacts is 20±3, 15±4 and 19±3 times and average welding force is 522.8N , 441.8N and 908.8N.","PeriodicalId":392306,"journal":{"name":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"94 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE-ST.2019.8928675","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
This paper compared the interruption , anti-welding and voltage withstand abilities of CuCr30 manufactured by three different ways, in which the influence of different manufactured ways on the electrical performance of vacuum interrupter (VI) was investigated. These results can worked as a reference for the selection of CuCr contacts used in the VI. The tested results compared the electrical performance under various CuCr30 manufactured by three different ways. Firstly, the results indicate that for arc-melted(VAR), powder metallurgy(PM) and vacuum casting(VIM) contacts power frequency withstand ability of those contacts can up to 65.9kV to 55.45kV 56.1kV respective.Secondly interruption times of those contacts is 20±3, 15±4 and 19±3 times and average welding force is 522.8N , 441.8N and 908.8N.