{"title":"Study on the impacts of wind farms on outgoing line relay protection based on the development of digital-physical hybrid simulation system for VSCF wind turbine","authors":"Jin Wang, Baohui Zhang, Guanghui Li, Z. Bo, David Writer, T. Yip","doi":"10.1109/APAP.2011.6180488","DOIUrl":null,"url":null,"abstract":"Major features of IEC 61850 include SCL-based engineering, uniform data model and communication-based information transfer. Owing to XML-based characteristics of SCL, a substation engineering can be done easily with programming. There are four kinds of information file in the SCL-based engineering - SSD (System Specification Description), ICD (IED Capability Description), CID (Configured IED Description) and SCD (Substation Configuration Description). The SCD file has all information about substation configuration. From SCD file, data or information of interest can be easily extracted using SCL parser and they can be stored in the database automatically.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Major features of IEC 61850 include SCL-based engineering, uniform data model and communication-based information transfer. Owing to XML-based characteristics of SCL, a substation engineering can be done easily with programming. There are four kinds of information file in the SCL-based engineering - SSD (System Specification Description), ICD (IED Capability Description), CID (Configured IED Description) and SCD (Substation Configuration Description). The SCD file has all information about substation configuration. From SCD file, data or information of interest can be easily extracted using SCL parser and they can be stored in the database automatically.