{"title":"A comparative study to evaluate the retention of conventional retention sleeve material versus retention.sil 600 in implant-retained overdentures: In vitro study","authors":"S. Khan, G. Issar, Siddharth Bansal, H. Jagadeesh, S. Tyagi","doi":"10.4103/jdi.jdi_14_20","DOIUrl":null,"url":null,"abstract":"Purpose: The aim of this study was to assess and evaluate the retention of conventional retentive sleeve material versus retention.sil in implant-retained overdentures. Methodology: Custom-designed models of uniform dimensions were made from heat-polymerized polymethyl methacrylate resin. The model had two components which comprised a lower member (matrix) and an upper member (patrix). The lower member (matrix) was embedded with two ADIN implant analogs attachment (Adin Implant System Ltd. Israel) of 3.75 mm × 10 mm with prefabricated ball attachment at an interimplant distance of 20 mm. The upper member was prepared to receive two different retention sleeve materials, conventional retentive/plastic sleeve attachment (Adin Implant System Ltd. Israel), and retention.sil 600 (Bredent medical GmbH and Co. KG). Using a universal testing machine, each of the models was subjected to 100 pulls each to dislodge the upper member from the lower member, and the force values as indicated on the digital indicator were tabulated. Statistical Analysis Used: Statistical analysis comprised Kolmogorov–Smirnov test, Friedman test, Mann–Whitney test, and Wilcoxon signed-rank test. Results: The statistical model revealed that when subjected to vertically directed forces, the conventional retentive/plastic sleeve attachment (Adin Implant System Ltd. Israel) developed higher retentive force as compared to the retention.sil 600 (Bredent medical GmbH and Co. KG). Conclusions: The conventional retentive sleeve material maintains their retentive capacity longer than the retention.sil 600. Further research is required to increase the retentive force in retention.sil material, thereby increasing denture retention and stability.","PeriodicalId":212982,"journal":{"name":"Journal of Dental Implants","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jdi.jdi_14_20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study was to assess and evaluate the retention of conventional retentive sleeve material versus retention.sil in implant-retained overdentures. Methodology: Custom-designed models of uniform dimensions were made from heat-polymerized polymethyl methacrylate resin. The model had two components which comprised a lower member (matrix) and an upper member (patrix). The lower member (matrix) was embedded with two ADIN implant analogs attachment (Adin Implant System Ltd. Israel) of 3.75 mm × 10 mm with prefabricated ball attachment at an interimplant distance of 20 mm. The upper member was prepared to receive two different retention sleeve materials, conventional retentive/plastic sleeve attachment (Adin Implant System Ltd. Israel), and retention.sil 600 (Bredent medical GmbH and Co. KG). Using a universal testing machine, each of the models was subjected to 100 pulls each to dislodge the upper member from the lower member, and the force values as indicated on the digital indicator were tabulated. Statistical Analysis Used: Statistical analysis comprised Kolmogorov–Smirnov test, Friedman test, Mann–Whitney test, and Wilcoxon signed-rank test. Results: The statistical model revealed that when subjected to vertically directed forces, the conventional retentive/plastic sleeve attachment (Adin Implant System Ltd. Israel) developed higher retentive force as compared to the retention.sil 600 (Bredent medical GmbH and Co. KG). Conclusions: The conventional retentive sleeve material maintains their retentive capacity longer than the retention.sil 600. Further research is required to increase the retentive force in retention.sil material, thereby increasing denture retention and stability.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一项评估传统固位套筒材料与固位的比较研究。种植保留覆盖义齿:体外研究
目的:本研究的目的是评估传统固位套筒材料与固位材料的固位效果。仍然在种植保留覆盖义齿。方法:采用热聚合聚甲基丙烯酸甲酯树脂制作统一尺寸的定制模型。该模型由下成员(矩阵)和上成员(矩阵)组成。下部构件(基质)嵌入两个ADIN植入物类似物附件(ADIN implant System Ltd.)。以色列)3.75 mm × 10 mm,在种植体间距离为20 mm的预制球附着体。上肢准备接受两种不同的固位套筒材料,传统的固位/塑料套筒附件(Adin Implant System Ltd.)。以色列)和保留率。sil600 (Bredent medical GmbH and Co. KG)。使用万能试验机,每个模型都受到100次拉力,每次拉力使上构件从下构件中脱落,并将数字指示器上显示的力值制成表格。统计分析方法:统计分析包括Kolmogorov-Smirnov检验、Friedman检验、Mann-Whitney检验和Wilcoxon sign -rank检验。结果:统计模型显示,当受到垂直方向的力时,传统的固位体/塑料套管附着体(Adin Implant System Ltd.)。以色列的留存力比美国的留存力高。sil600 (Bredent medical GmbH and Co. KG)。结论:常规固位套筒材料比固位套筒材料保持固位能力更长。银600。提高固位力的方法有待进一步研究。Sil材料,从而增加义齿固位和稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Piezo osteotomy with all-on-4 implants to enable a full-arch rehabilitation A comparative evaluation of bite pressure between single implant prosthesis and natural teeth: An in-vivo study Two implant-retained mandibular overdenture using locator attachment – A clinical report Systemic medications and implant success: Is there a link? Part three: The effects of antiresorptive and anti-angiogenic agents on the outcome of implant therapy Gender-based predilection for the microbial load of Aggregatibacter actinomycetemcomitans present in anterior versus posterior implant sites: A preliminary observational study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1