{"title":"Noninvasive method for rotor fault diagnosis in the inverter fed induction motor drive","authors":"P. Kołodziejek","doi":"10.1109/EVER.2013.6521586","DOIUrl":null,"url":null,"abstract":"This article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.","PeriodicalId":386323,"journal":{"name":"2013 Eighth International Conference and Exhibition on Ecological Vehicles and Renewable Energies (EVER)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Eighth International Conference and Exhibition on Ecological Vehicles and Renewable Energies (EVER)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EVER.2013.6521586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
This article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.