{"title":"A virtual instrument for the determination of the electric power quality","authors":"L. Cristaldi, A. Ferrero","doi":"10.1109/IMTC.1994.351816","DOIUrl":null,"url":null,"abstract":"The number and power of loads that pollute, from an electric point of view, the electric network (non-linear, time-variant loads, ...) is constantly increasing. Their connection to the electric network causes a significant distortion in the line current and, when their overall power is no longer negligible with respect to the network power, also some distortion in the line voltage, thus deteriorating the electric supply quality. The availability of accurate instruments able to detect the presence of a polluting load and to quantify the resulting deterioration of the supply quality is hence an important and critical point for the correct operation of the electric power system. The paper proposes a method, based on the evaluation of the harmonic powers, to identify whether the source producing distortion in the line currents and voltages of a three-phase system is the presence of a polluting load after the metering section or is the distortion of the line voltages. Some parameters are also defined in order to quantify the effects of the polluting load on the power quality. A Virtual Instrument is also described, realized to implement the proposed method and to verify it experimentally. The instrument accuracy is discussed.<<ETX>>","PeriodicalId":231484,"journal":{"name":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1994.351816","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

The number and power of loads that pollute, from an electric point of view, the electric network (non-linear, time-variant loads, ...) is constantly increasing. Their connection to the electric network causes a significant distortion in the line current and, when their overall power is no longer negligible with respect to the network power, also some distortion in the line voltage, thus deteriorating the electric supply quality. The availability of accurate instruments able to detect the presence of a polluting load and to quantify the resulting deterioration of the supply quality is hence an important and critical point for the correct operation of the electric power system. The paper proposes a method, based on the evaluation of the harmonic powers, to identify whether the source producing distortion in the line currents and voltages of a three-phase system is the presence of a polluting load after the metering section or is the distortion of the line voltages. Some parameters are also defined in order to quantify the effects of the polluting load on the power quality. A Virtual Instrument is also described, realized to implement the proposed method and to verify it experimentally. The instrument accuracy is discussed.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于测定电能质量的虚拟仪器
从电力的角度来看,污染电网的负荷(非线性、时变负荷等)的数量和功率都在不断增加。它们与电网的连接使线路电流产生明显的畸变,当它们的总功率相对于电网功率不再可以忽略不计时,线路电压也会产生一定的畸变,从而使供电质量恶化。因此,能否使用精确的仪器来检测污染负荷的存在,并量化由此导致的供电质量的恶化,是电力系统正确运行的一个重要而关键的问题。本文提出了一种基于谐波功率评估的方法,来判断三相系统中产生线路电流和电压畸变的源是计量段后存在污染负荷还是线路电压畸变。为了量化污染负荷对电能质量的影响,还定义了一些参数。本文还描述并实现了一个虚拟仪器来实现所提出的方法,并进行了实验验证。对仪器的精度进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Definition and analysis of an electronic device for synchronous circular sampling of locally periodic signals An optical instrumentation using dual sensor-dummy against noises Curvisensors for inside and outside robot arms A quartz crystal microbalance-type odor sensor using PVC-blended lipid membrane Locally mounted process gas analyzing system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1