Wearable instrument to measure simultaneously cardiac and electrodermal activities

A. Affanni
{"title":"Wearable instrument to measure simultaneously cardiac and electrodermal activities","authors":"A. Affanni","doi":"10.1109/MeMeA.2016.7533749","DOIUrl":null,"url":null,"abstract":"The paper presents the design and characterization of a wearable instrument which measures simultaneously the electrodermal activity and the heart rate variability. The device measures the electrocardiogram on three channels and the skin potential response (endosomatic electrodermal activity) with a sample rate 1 kSa/s, 12 bits resolution. The bandwidth of ECG channels is [0.025, 160] Hz and the bandwidth of electrodermal channel is [0.08, 40] Hz. Data are transmitted via Bluetooth to a developed graphical user interface, which can run on a laptop or smartphone/tablet. The system is a useful tool to assess the sympathetic activity on heart rate variability.","PeriodicalId":221120,"journal":{"name":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2016.7533749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

The paper presents the design and characterization of a wearable instrument which measures simultaneously the electrodermal activity and the heart rate variability. The device measures the electrocardiogram on three channels and the skin potential response (endosomatic electrodermal activity) with a sample rate 1 kSa/s, 12 bits resolution. The bandwidth of ECG channels is [0.025, 160] Hz and the bandwidth of electrodermal channel is [0.08, 40] Hz. Data are transmitted via Bluetooth to a developed graphical user interface, which can run on a laptop or smartphone/tablet. The system is a useful tool to assess the sympathetic activity on heart rate variability.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
同时测量心脏和皮肤电活动的穿戴式仪器
本文介绍了一种可同时测量皮肤电活动和心率变异性的可穿戴仪器的设计和特性。该装置以1 kSa/s的采样率,12位分辨率测量三个通道上的心电图和皮肤电位反应(内体皮电活动)。心电通道带宽为[0.025,160]Hz,皮肤电通道带宽为[0.08,40]Hz。数据通过蓝牙传输到一个开发的图形用户界面,可以在笔记本电脑或智能手机/平板电脑上运行。该系统是评估交感神经活动对心率变异性的有用工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation of temperature rise in tissue — Mimicking material induced by a HIFU transducer Influence of fiber Bragg grating length on temperature measurements in laser-irradiated organs Optimal peripheral measurement point for the assessment of preterm patients in intensive care units Classification of cognitive and resting states of the brain using EEG features Scoring systems in dermatology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1