Electrical endurance capability of vacuum circuit breakers: Standards and tests results for MV equipment

G. Sandolache, L. Gaches, S. Melquiond, S. Chakraborty
{"title":"Electrical endurance capability of vacuum circuit breakers: Standards and tests results for MV equipment","authors":"G. Sandolache, L. Gaches, S. Melquiond, S. Chakraborty","doi":"10.1109/ICEPE-ST.2011.6122939","DOIUrl":null,"url":null,"abstract":"Electrical endurance capability of circuit breakers is mostly demanded for sound economic reasons in order to verify the cumulative energy that may be interrupted without maintenance during the lifetime of the equipment. Reliability of the vacuum circuit breakers has been proven by superior electrical endurance at short-circuits current. Standards, particularly IEC, ANSI, JT, GB, GOST, present various test programs relative to the electrical endurance E2 class ability, the differentiation between being done by the type and number of operating sequences, testing current and successful criteria to pass the test. The paper presents the electrical endurance results obtained in respect with different standard testing programs for MV circuit breaker 40kV/ 25kA.","PeriodicalId":379448,"journal":{"name":"2011 1st International Conference on Electric Power Equipment - Switching Technology","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 1st International Conference on Electric Power Equipment - Switching Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE-ST.2011.6122939","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Electrical endurance capability of circuit breakers is mostly demanded for sound economic reasons in order to verify the cumulative energy that may be interrupted without maintenance during the lifetime of the equipment. Reliability of the vacuum circuit breakers has been proven by superior electrical endurance at short-circuits current. Standards, particularly IEC, ANSI, JT, GB, GOST, present various test programs relative to the electrical endurance E2 class ability, the differentiation between being done by the type and number of operating sequences, testing current and successful criteria to pass the test. The paper presents the electrical endurance results obtained in respect with different standard testing programs for MV circuit breaker 40kV/ 25kA.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
真空断路器的电气耐久性能。中压设备标准和试验结果
为了验证在设备使用寿命期间无需维护而可能中断的累积能量,对断路器的电气续航能力的要求主要是出于合理的经济原因。真空断路器的可靠性已被证明在短路电流下具有优异的电气耐久性。标准,特别是IEC, ANSI, JT, GB, GOST,提出了各种测试程序相对于电气耐久性E2级能力,被做的区分操作顺序的类型和数量,测试电流和成功的标准,以通过测试。本文介绍了40kV/ 25kA中压断路器在不同标准试验方案下的电气耐久性试验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
HVDC system for a data center equipped with SiC power devices Studies of high current arcs using an optical fiber array based imaging system Experimental investigation on the gas flow motion of puffer circuit breaker Feasibility study of metalized membrane method applied to monitoring corona loss of AC/ DC transmission line Interrupter pressure measurement of a 252 kV SF6 circuit breaker
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1