Inverters and compensators for minimum line losses

M. Malengret, C. Gaunt
{"title":"Inverters and compensators for minimum line losses","authors":"M. Malengret, C. Gaunt","doi":"10.1109/EPE.2016.7695634","DOIUrl":null,"url":null,"abstract":"The local control of inverters and compensators, based on measurements of the power system and calculation of the optimum current to be injected into each phase, has been tested in simulation and implemented in hardware with a rating of 24 kW, with results as predicted by the general power theory. The approach is scalable for ac and dc systems.","PeriodicalId":119358,"journal":{"name":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2016.7695634","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

The local control of inverters and compensators, based on measurements of the power system and calculation of the optimum current to be injected into each phase, has been tested in simulation and implemented in hardware with a rating of 24 kW, with results as predicted by the general power theory. The approach is scalable for ac and dc systems.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于最小线路损耗的逆变器和补偿器
逆变器和补偿器的局部控制是基于对电力系统的测量和对每个相位注入的最佳电流的计算,已经在模拟中进行了测试,并在额定功率为24 kW的硬件上实现了,结果与一般功率理论预测的结果一致。该方法适用于交流和直流系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Continuous control set space vector modulation for the 3×3 direct matrix converter Connector-less SiC power modules with integrated shunt — Low-profile design for low inductance and low cost DC microgrid power coordination based on fuzzy logic control Design and implementation of magnetron power supply and emulator Virtual synchronous-machine control of voltage-source converters in a low-voltage microgrid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1