{"title":"A new method to prevent distance protection from operating due to power swing","authors":"A. Pahlevan, J. Sadeh","doi":"10.1109/APAP.2011.6180736","DOIUrl":null,"url":null,"abstract":"A power swing may cause unwanted tripping of the distance protection. The power swing blocking is a function commonly used to prevent the distance protection from operating during power swing. When a distance relay is blocked, it cannot react to faults anymore. This paper proposes a new method to prevent this protection from operating during power swing condition when no fault occurs. In this method, swings are removed from the voltage and current signals, using (d-q) frame, and then these signals are used in the impedance calculation of the distance relay. So, the distance protection is not blocked and can trip when a fault occurs. Simulation results are presented for a typical system using PSCAD software.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A power swing may cause unwanted tripping of the distance protection. The power swing blocking is a function commonly used to prevent the distance protection from operating during power swing. When a distance relay is blocked, it cannot react to faults anymore. This paper proposes a new method to prevent this protection from operating during power swing condition when no fault occurs. In this method, swings are removed from the voltage and current signals, using (d-q) frame, and then these signals are used in the impedance calculation of the distance relay. So, the distance protection is not blocked and can trip when a fault occurs. Simulation results are presented for a typical system using PSCAD software.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种防止距离保护因功率摆动而失效的新方法
功率摆动可能导致不必要的距离保护跳闸。功率摆挡是一种常用的防止功率摆时距离保护动作的功能。当距离继电器被阻塞时,它不能再对故障作出反应。本文提出了一种防止该保护装置在无故障情况下在功率摇摆状态下运行的新方法。该方法利用(d-q)帧去除电压和电流信号的振荡,然后将这些信号用于距离继电器的阻抗计算。因此,当发生故障时,距离保护不会被阻塞,并且可以跳闸。利用PSCAD软件对一个典型系统进行了仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Matlab-based voltage stability analysis toolbox and its validity check Fault indicator allocation in power distribution network for improving reliability and fault section estimation Effect of monitoring and self-checking tests effectiveness index of back-up protection system on the optimum routine and self-checking test intervals of protection system A new method to prevent distance protection from operating due to power swing Coordination of overcurrent and distance relays using hybrid Particle Swarm Optimization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1