{"title":"Inductance Measurement Using an LCR Meter and a Current Transformer Interface","authors":"B. Waltrip, S. Avramov-Zamurovic, A. Koffman","doi":"10.1109/IMTC.2005.1604290","DOIUrl":null,"url":null,"abstract":"This paper describes a new inductance measurement system based on a commercially available LCR meter, a commercially available audio frequency capacitance bridge, 4 terminal-pair (4TP) capacitance and resistance standards, and a multi-stage, programmable-ratio, current transformer. The described measurement system synthesizes equivalent inductance values using the current transformer to combine the applied currents through programmable resistance and capacitance standards. The system takes advantage of the inherent measurement linearity of the LCR meter, and achieves acceptable inductance measurement uncertainty over the 50 Hz to 20 kHz frequency range","PeriodicalId":244878,"journal":{"name":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2005.1604290","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

This paper describes a new inductance measurement system based on a commercially available LCR meter, a commercially available audio frequency capacitance bridge, 4 terminal-pair (4TP) capacitance and resistance standards, and a multi-stage, programmable-ratio, current transformer. The described measurement system synthesizes equivalent inductance values using the current transformer to combine the applied currents through programmable resistance and capacitance standards. The system takes advantage of the inherent measurement linearity of the LCR meter, and achieves acceptable inductance measurement uncertainty over the 50 Hz to 20 kHz frequency range
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电感测量使用LCR表和电流互感器接口
本文介绍了一种新的电感测量系统,该系统基于市售LCR表、市售音频电容桥、4个终端对(4TP)电容和电阻标准以及多级可编程比电流互感器。所描述的测量系统利用电流互感器通过可编程电阻和电容标准来组合施加的电流,从而合成等效电感值。该系统利用LCR表固有的测量线性度,在50 Hz ~ 20 kHz频率范围内实现了可接受的电感测量不确定度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Low-Cost Real-Time Virtual Spectrum Analyzer Determination of thickness and dielectric constant of coatings from capacitance measurements Noninvasive Measurement of Blood Glucose Based on Optical Sensing and Internal Standard Method A Technique for Image Denoising Based on Adaptive Piecewise Linear Filters and Automatic Parameter Tuning Error Recovery Service for the IEEE 802.11B Protocol
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1