{"title":"A classification system of lung nodules in CT images based on fractional Brownian motion model","authors":"P. Huang, P. Lin, Cheng-Hsiung Lee, C. Kuo","doi":"10.1109/ICSSE.2013.6614710","DOIUrl":null,"url":null,"abstract":"In this paper, we present a classification system for differentiating malignant pulmonary nodules from benign nodules in computed tomography (CT) images based on a set of fractal features derived from the fractional Brownian motion (fBm) model. In a set of 107 CT images obtained from 107 different patients with each image containing a solitary pulmonary nodule, our experimental result show that the accuracy rate of classification and the area under the Receiver Operating Characteristic (ROC) curve are 83.11% and 0.8437, respectively, by using the proposed fractal-based feature set and a support vector machine classifier. Such a result demonstrates that our classification system has highly satisfactory diagnostic performance by analyzing the fractal features of lung nodules in CT images taken from a single post-contrast CT scan.","PeriodicalId":124317,"journal":{"name":"2013 International Conference on System Science and Engineering (ICSSE)","volume":"73 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference on System Science and Engineering (ICSSE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSSE.2013.6614710","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17
Abstract
In this paper, we present a classification system for differentiating malignant pulmonary nodules from benign nodules in computed tomography (CT) images based on a set of fractal features derived from the fractional Brownian motion (fBm) model. In a set of 107 CT images obtained from 107 different patients with each image containing a solitary pulmonary nodule, our experimental result show that the accuracy rate of classification and the area under the Receiver Operating Characteristic (ROC) curve are 83.11% and 0.8437, respectively, by using the proposed fractal-based feature set and a support vector machine classifier. Such a result demonstrates that our classification system has highly satisfactory diagnostic performance by analyzing the fractal features of lung nodules in CT images taken from a single post-contrast CT scan.