A novel approach for comparison of heart rate variability derived from synchronously measured electrocardiogram and photoplethysmogram

R. R. Lekkala, Srinivas Kuntamalla
{"title":"A novel approach for comparison of heart rate variability derived from synchronously measured electrocardiogram and photoplethysmogram","authors":"R. R. Lekkala, Srinivas Kuntamalla","doi":"10.1109/HIC.2017.8227599","DOIUrl":null,"url":null,"abstract":"Currently, heart Rate Variability (HRV) is derived from ECG. Many researchers have explored the usefulness of photoplethysmography (PPG), for the analysis of HRV. However, all these studies are based on statistical approach and used the correlation coefficient for comparing the two data sets obtained using ECG and PPG, which is inappropriate as the causal relationship between the R-peaks in ECG and the peaks in PPG is a physiologically established fact. In this study, the heart beat intervals measured from PPG, are compared, beat by beat, by taking the corresponding beat intervals of same cardiac cycle obtained from ECG and the measurement error is quantized. The error is found to be within 2% across the entire sample of 42 subjects, in spite of diversified constitution of the study group in terms of age, sex and pathology. Errors are also interpreted in terms of variations in pulse transit time. A very good agreement is found between the ECG and PPG derived parameters of HRV. In view of these findings, it may be concluded that PPG provides a safer and low cost option, in place of ECG, as a wearable sensor outside hospital environment, for the analysis of HRV, without compromising on accuracy.","PeriodicalId":120815,"journal":{"name":"2017 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT)","volume":"6 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HIC.2017.8227599","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Currently, heart Rate Variability (HRV) is derived from ECG. Many researchers have explored the usefulness of photoplethysmography (PPG), for the analysis of HRV. However, all these studies are based on statistical approach and used the correlation coefficient for comparing the two data sets obtained using ECG and PPG, which is inappropriate as the causal relationship between the R-peaks in ECG and the peaks in PPG is a physiologically established fact. In this study, the heart beat intervals measured from PPG, are compared, beat by beat, by taking the corresponding beat intervals of same cardiac cycle obtained from ECG and the measurement error is quantized. The error is found to be within 2% across the entire sample of 42 subjects, in spite of diversified constitution of the study group in terms of age, sex and pathology. Errors are also interpreted in terms of variations in pulse transit time. A very good agreement is found between the ECG and PPG derived parameters of HRV. In view of these findings, it may be concluded that PPG provides a safer and low cost option, in place of ECG, as a wearable sensor outside hospital environment, for the analysis of HRV, without compromising on accuracy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种比较同步测量心电图和光容积描记图的心率变异性的新方法
目前,心率变异性(HRV)是由心电图得出的。许多研究者探索了光容积脉搏波(PPG)在HRV分析中的作用。然而,这些研究都是基于统计方法,使用相关系数来比较ECG和PPG得到的两个数据集,这是不合适的,因为ECG的r峰与PPG的峰之间的因果关系是生理上既定的事实。在本研究中,通过取同一心电周期的相应心跳间隔,逐次比较PPG测得的心跳间隔,并对测量误差进行量化。尽管研究组在年龄、性别和病理方面构成多样化,但在42个受试者的整个样本中,误差被发现在2%以内。误差也可以用脉冲传递时间的变化来解释。心电和PPG计算的HRV参数吻合得很好。鉴于这些发现,可以得出结论,PPG作为医院外环境的可穿戴传感器,在不影响准确性的情况下,代替ECG,为HRV分析提供了一种更安全、更低成本的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Label-free detection of lactoferrin and beta-2-microglobuin in contrived tear film using a low-cost electrical biosensor chip Development of an AI-based non-invasive Pulse AudioGram monitoring device for arrhythmia screening Comparison of sleep parameters assessed by actigraphy of healthy young adults from a small town and a megalopolis in an emerging country A dedicated bit-serial hardware neuron for massively-parallel neural networks in fast epilepsy diagnosis A feasibility study on a low-cost, smartphone-based solution of pulse transit time measurement using cardio-mechanical signals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1