Current-Mode Temporal Difference CMOS Imager for Capsule Endoscopy

Ho Yeung Chan, Jie Yuan
{"title":"Current-Mode Temporal Difference CMOS Imager for Capsule Endoscopy","authors":"Ho Yeung Chan, Jie Yuan","doi":"10.1109/BIOCAS.2007.4463348","DOIUrl":null,"url":null,"abstract":"A current-mode temporal difference imager for wireless capsule-endoscopy is introduced. The new imager generates low output data rate. Wide dynamic range image can be recovered from the low-rate data at the receiver side. To reduce the circuit charge injection error of the difference imager, a calibration technique for the pixel is developed, and introduced in the paper. The image restoration error is found to be bounded for our calibration scheme. With a designed estimation function, the restoration error is suppressed below 0.1 pA, which enables the imager with 95 dB dynamic range. The hardware cost of the decoder for the calibration scheme is moderate.","PeriodicalId":273819,"journal":{"name":"2007 IEEE Biomedical Circuits and Systems Conference","volume":"2672 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Biomedical Circuits and Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2007.4463348","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A current-mode temporal difference imager for wireless capsule-endoscopy is introduced. The new imager generates low output data rate. Wide dynamic range image can be recovered from the low-rate data at the receiver side. To reduce the circuit charge injection error of the difference imager, a calibration technique for the pixel is developed, and introduced in the paper. The image restoration error is found to be bounded for our calibration scheme. With a designed estimation function, the restoration error is suppressed below 0.1 pA, which enables the imager with 95 dB dynamic range. The hardware cost of the decoder for the calibration scheme is moderate.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于胶囊内窥镜的电流模时间差CMOS成像仪
介绍了一种用于无线胶囊内窥镜的电流模式时间差成像仪。新的成像仪产生低输出数据速率。从接收端的低速率数据中可以恢复出宽动态范围的图像。为了减小差分成像仪的电路电荷注入误差,本文提出了一种像元校正技术。发现我们的校正方案的图像恢复误差是有界的。通过设计的估计函数,恢复误差被抑制在0.1 pA以下,使成像仪具有95 dB的动态范围。该校准方案的解码器硬件成本适中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Breast Lesions Classification Using Modified Non-Recursive Discrete Biorthogonal Wavelet Transform Efficient Computation of the LF/HF Ratio in Heart Rate Variability Analysis Based on Bitstream Filtering On the Swept-threshold Sampling in UWB Medical Radar Long-term monitoring of electrochemical parameters from stimulated neural tissues A Mixed-Signal Multi-Chip Neural Recording Interface with Bandwidth Reduction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1