{"title":"Harmonic-domain analysis of AC machine with magnetic saturation by finite element method","authors":"S. Yamada, M. Iwahara, K. Bessho","doi":"10.1109/CIPE.1994.396702","DOIUrl":null,"url":null,"abstract":"This paper presents a new three-dimensional finite element analysis to AC electromagnetic machines with nonlinear magnetic characteristics in a steady state. The method enables calculation of the time-periodic (nonsinusoidal) characteristics in the harmonic domain. Unlike field calculations in time domain, only the steady-state solution can be obtained directly. The application of parallel processing to this approach is discussed. The analyses of an inductor with a shading coil and a model of a flux-concentration type electromagnetic pump are also presented.<<ETX>>","PeriodicalId":123138,"journal":{"name":"Proceedings of 1994 IEEE Workshop on Computers in Power Electronics","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 IEEE Workshop on Computers in Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIPE.1994.396702","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents a new three-dimensional finite element analysis to AC electromagnetic machines with nonlinear magnetic characteristics in a steady state. The method enables calculation of the time-periodic (nonsinusoidal) characteristics in the harmonic domain. Unlike field calculations in time domain, only the steady-state solution can be obtained directly. The application of parallel processing to this approach is discussed. The analyses of an inductor with a shading coil and a model of a flux-concentration type electromagnetic pump are also presented.<>