40-GHz vital sign detection of heartbeat using synchronized motion technique for respiration signal suppression

J. Cheng, Jin-Fu Yeh, Hong-Yuan Yang, Jeng‐Han Tsai, Jenshan Lin, Tian-Wei Huang
{"title":"40-GHz vital sign detection of heartbeat using synchronized motion technique for respiration signal suppression","authors":"J. Cheng, Jin-Fu Yeh, Hong-Yuan Yang, Jeng‐Han Tsai, Jenshan Lin, Tian-Wei Huang","doi":"10.23919/EUMC.2012.6459289","DOIUrl":null,"url":null,"abstract":"The vital sign, including respiration and heartbeat signal, can be detected through a non-contact Doppler radar. Since the harmonics and intermodulation products of the respiration are major interferences according to the previous researches, the heartbeat signal cannot be clearly identified without holding the breath, detected from back of the subject or just filtered to remove respiration signal. A synchronized motion technique (SMT) based on Doppler concept is proposed to suppress the interference from the respiration in non-contact heartbeat detection. The experiment results show that the SMT effectively improve the heartbeat-to-respiration ratio (HRR) up to 76 % while subject kept normal breathing. The SMT mechanism is also analyzed through non-linear simulation which agrees well with the measurement data.","PeriodicalId":266910,"journal":{"name":"2012 42nd European Microwave Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 42nd European Microwave Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/EUMC.2012.6459289","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The vital sign, including respiration and heartbeat signal, can be detected through a non-contact Doppler radar. Since the harmonics and intermodulation products of the respiration are major interferences according to the previous researches, the heartbeat signal cannot be clearly identified without holding the breath, detected from back of the subject or just filtered to remove respiration signal. A synchronized motion technique (SMT) based on Doppler concept is proposed to suppress the interference from the respiration in non-contact heartbeat detection. The experiment results show that the SMT effectively improve the heartbeat-to-respiration ratio (HRR) up to 76 % while subject kept normal breathing. The SMT mechanism is also analyzed through non-linear simulation which agrees well with the measurement data.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用同步运动技术抑制呼吸信号的40 ghz心跳生命体征检测
生命体征,包括呼吸和心跳信号,可以通过非接触式多普勒雷达检测到。根据以往的研究,由于呼吸的谐波和互调产物是主要的干扰,如果不屏住呼吸,从被试的背后检测,或者只是过滤掉呼吸信号,就无法清晰地识别心跳信号。提出了一种基于多普勒概念的同步运动技术来抑制非接触式心跳检测中呼吸的干扰。实验结果表明,在受试者保持正常呼吸的情况下,SMT可有效提高心跳呼吸比(HRR)达76%。通过非线性仿真分析了SMT的机理,与实测数据吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Composite right/left-handed (CRLH) phased-array feed network for frequency scanning antenna Treatment planning guided RF hyperthermia EMF hyperthermia in children Frequency-independent smart interference suppression for multi-standard transceivers MR and hyperthermia: Exploiting similarities for mutual benefit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1