Multi-cell operation of a high-frequency isolated DC/AC converter for grid-connected wind generation applications

Xiaodong Li, A. Bhat
{"title":"Multi-cell operation of a high-frequency isolated DC/AC converter for grid-connected wind generation applications","authors":"Xiaodong Li, A. Bhat","doi":"10.1109/ICIINFS.2009.5429869","DOIUrl":null,"url":null,"abstract":"A high-frequency (HF) isolated DC/AC converter was proposed as the interface between a small-scale PMSG-based wind turbine generation system (WTGS) and a single-phase utility line in [4]. In this paper after a brief review of this configuration, different options of the multi-cell operation of this converter for high power wind generation applications are discussed. The effect of multi-cell operation on the harmonics on the input dc current and output line currents are addressed. It is found that both the 2nd harmonic in the input dc current and all triplen harmonics in the output line currents are eliminated when three identical single-phase converters in Delta connection are used. PSIM simulation results are included for the purpose of validation.","PeriodicalId":117199,"journal":{"name":"2009 International Conference on Industrial and Information Systems (ICIIS)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Industrial and Information Systems (ICIIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIINFS.2009.5429869","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

A high-frequency (HF) isolated DC/AC converter was proposed as the interface between a small-scale PMSG-based wind turbine generation system (WTGS) and a single-phase utility line in [4]. In this paper after a brief review of this configuration, different options of the multi-cell operation of this converter for high power wind generation applications are discussed. The effect of multi-cell operation on the harmonics on the input dc current and output line currents are addressed. It is found that both the 2nd harmonic in the input dc current and all triplen harmonics in the output line currents are eliminated when three identical single-phase converters in Delta connection are used. PSIM simulation results are included for the purpose of validation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于并网风力发电应用的高频隔离DC/AC变换器的多单元运行
提出了一种高频隔离DC/AC变换器,作为小型永磁同步电动机风力发电系统(WTGS)与[4]单相公用线路之间的接口。在本文中,在对该配置进行简要回顾之后,讨论了用于大功率风力发电的该变流器的多单元运行的不同选择。讨论了多单元运行对输入直流电流和输出线路电流谐波的影响。结果表明,当采用三个相同的单相变换器采用三角连接时,输入直流电流中的二次谐波和输出线路电流中的所有三次谐波均被消除。为了验证,本文包含了PSIM模拟结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Resource-Allocating Codebook for patch-based face recognition HVDC transmission line for interconnecting power grids in India and Sri Lanka Case study of WSN as a replacement for SCADA An end to end correctness verification approach for application specific usage control An autonomous distributed vehicle-to-grid control of grid-connected electric vehicle
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1