{"title":"Histopathological examination of oral mucosal incisions welded by 980 nm Diode Laser in vivo","authors":"B. Mirdan","doi":"10.4103/0976-2868.106639","DOIUrl":null,"url":null,"abstract":"Continuous mode of operation (CW)980 nm Laser tissue welding has been studied for full thickness incisions on the oral cavity of the rabbit in vivo. Materials and Methods: Surgical incisions were done on the hard palate of the rabbits; the incisions were irradiated with 980 nm diode laser, 0.63 W as an output power and 27 s as an exposure time. Results: The immediate clinical results have shown a hemostasis of the bleeding, while the histopathological examination showed comparable results though it revealed a fastened healing pattern in comparison with the sutured incisions. Discussion: The immediately laser welded tissues was as a result of the denaturation and coagulation of the tissue proteins via the increase of the tissue temperature due to the laser-tissue photothermal interaction. Conclusion: The use of 980 nm diode laser in soft tissue welding is a successful method of wound closure in oral mucosa with the minimum side effects.","PeriodicalId":345720,"journal":{"name":"Journal of Dental Lasers","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Lasers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/0976-2868.106639","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Continuous mode of operation (CW)980 nm Laser tissue welding has been studied for full thickness incisions on the oral cavity of the rabbit in vivo. Materials and Methods: Surgical incisions were done on the hard palate of the rabbits; the incisions were irradiated with 980 nm diode laser, 0.63 W as an output power and 27 s as an exposure time. Results: The immediate clinical results have shown a hemostasis of the bleeding, while the histopathological examination showed comparable results though it revealed a fastened healing pattern in comparison with the sutured incisions. Discussion: The immediately laser welded tissues was as a result of the denaturation and coagulation of the tissue proteins via the increase of the tissue temperature due to the laser-tissue photothermal interaction. Conclusion: The use of 980 nm diode laser in soft tissue welding is a successful method of wound closure in oral mucosa with the minimum side effects.