Shunt active filter with sliding mode control

B. Lin, Zong-Liang Hung, Shuh-Chuan Tsay, Mu-Shan Liao
{"title":"Shunt active filter with sliding mode control","authors":"B. Lin, Zong-Liang Hung, Shuh-Chuan Tsay, Mu-Shan Liao","doi":"10.1109/TENCON.2001.949723","DOIUrl":null,"url":null,"abstract":"This paper presents a simple control scheme which adopted the voltage source inverter to decrease current harmonics generated by the nonlinear load. The sliding mode control is used in the current control loop to achieve fast dynamics. Only the source currents are measured in the proposed control scheme to reduce the elements of current sensors needed in the conventional control approach. A simple proportional-integral controller is adopted in the voltage control loop to achieve slow dynamics. The proposed scheme can achieve high power factor, current harmonic elimination and reactive power compensation. A diode rectifier fed capacitive load as the nonlinear load is taken on the AC mains to demonstrate the effectiveness of the shunt active filter for reactive power and current harmonics compensation.","PeriodicalId":358168,"journal":{"name":"Proceedings of IEEE Region 10 International Conference on Electrical and Electronic Technology. TENCON 2001 (Cat. No.01CH37239)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Region 10 International Conference on Electrical and Electronic Technology. TENCON 2001 (Cat. No.01CH37239)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCON.2001.949723","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

This paper presents a simple control scheme which adopted the voltage source inverter to decrease current harmonics generated by the nonlinear load. The sliding mode control is used in the current control loop to achieve fast dynamics. Only the source currents are measured in the proposed control scheme to reduce the elements of current sensors needed in the conventional control approach. A simple proportional-integral controller is adopted in the voltage control loop to achieve slow dynamics. The proposed scheme can achieve high power factor, current harmonic elimination and reactive power compensation. A diode rectifier fed capacitive load as the nonlinear load is taken on the AC mains to demonstrate the effectiveness of the shunt active filter for reactive power and current harmonics compensation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
带滑模控制的并联有源滤波器
本文提出了一种简单的控制方案,即采用电压源逆变器来降低非线性负载产生的电流谐波。电流控制回路采用滑模控制,实现快速动态控制。该控制方案仅测量源电流,减少了传统控制方法所需的电流传感器元件。电压控制回路采用简单的比例积分控制器实现慢动态。该方案可实现高功率因数、电流谐波消除和无功补偿。采用二极管整流馈电容性负载作为交流电源的非线性负载,验证了并联有源滤波器对无功功率和电流谐波补偿的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation of a fault tolerant and high performance motor drive for critical applications An optical fiber feeder system and performance for cellular microcell 800 MHz CDMA systems Reactive web policing based on self-organizing maps Features preserving filters using fuzzy Kohonen clustering network in detection of impulse noise Reliability modeling incorporating error processes for Internet-distributed software
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1