Informasi Citra Anatomi pada Penggunaan Variasi Increment Pemeriksaan MSCT Abdomen Irisan Axial Kasus Nodul Hepar

Selfia Claudiana Rahma Dewi, Arinawati Arinawati, Darmini Darmini, Dimas Prakoso
{"title":"Informasi Citra Anatomi pada Penggunaan Variasi Increment Pemeriksaan MSCT Abdomen Irisan Axial Kasus Nodul Hepar","authors":"Selfia Claudiana Rahma Dewi, Arinawati Arinawati, Darmini Darmini, Dimas Prakoso","doi":"10.31983/JIMED.V7I2.7462","DOIUrl":null,"url":null,"abstract":"Background : Liver nodules are tumors that are less than 2 cm in size and are single or multiple. In making a diagnosis of liver nodules can be done by examination of abdominal MSCT. According to Seeram (2009), using 50% overlapping there was an increase in nodule detection by 10% compared to incremental increments. The purpose of the study was to determine differences in information on anatomical images on the use of increment variations in abdominal MSCT examination and to find the appropriate increment values to produce optimal anatomical image information.Methods : This type of research is quantitative with an experimental approach. The study was conducted at the RSUD. Tugurejo Semarang, the image was taken from abdominal MSCT examination in 5 patients with a variation of increments of 100% (8 mm), 50% (4 mm), 30% (2, 4 mm). The results of the study were assessed by 3 respondents. Data analysis used the kappa statistical test, crosstabulation, and friedman.Results : From the statistical test, the results of the 2.4 mm increment value show clear anatomical criteria and can detect small nodules. Supported by using friedman statistical test p-value = 0.000 which means that p-value 0.05 thus Ha is accepted so that there are differences in anatomical image information.Conclusion : The most optimal increment value is 30% (2.4 mm) because it has the highest mean rank value of 2.37.","PeriodicalId":205622,"journal":{"name":"Jurnal Imejing Diagnostik (JImeD)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Imejing Diagnostik (JImeD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31983/JIMED.V7I2.7462","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background : Liver nodules are tumors that are less than 2 cm in size and are single or multiple. In making a diagnosis of liver nodules can be done by examination of abdominal MSCT. According to Seeram (2009), using 50% overlapping there was an increase in nodule detection by 10% compared to incremental increments. The purpose of the study was to determine differences in information on anatomical images on the use of increment variations in abdominal MSCT examination and to find the appropriate increment values to produce optimal anatomical image information.Methods : This type of research is quantitative with an experimental approach. The study was conducted at the RSUD. Tugurejo Semarang, the image was taken from abdominal MSCT examination in 5 patients with a variation of increments of 100% (8 mm), 50% (4 mm), 30% (2, 4 mm). The results of the study were assessed by 3 respondents. Data analysis used the kappa statistical test, crosstabulation, and friedman.Results : From the statistical test, the results of the 2.4 mm increment value show clear anatomical criteria and can detect small nodules. Supported by using friedman statistical test p-value = 0.000 which means that p-value 0.05 thus Ha is accepted so that there are differences in anatomical image information.Conclusion : The most optimal increment value is 30% (2.4 mm) because it has the highest mean rank value of 2.37.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
背景:肝结节是体积小于2cm的肿瘤,可单发或多发。在诊断肝结节时,可通过腹部MSCT检查。根据Seeram(2009)的研究,使用50%的重叠与增量相比,结节的检出率增加了10%。本研究的目的是确定在腹部MSCT检查中使用增量变化在解剖图像上的信息差异,并找到适当的增量值来产生最佳的解剖图像信息。方法:这种类型的研究是定量与实验的方法。这项研究在RSUD进行。Tugurejo Semarang,该图像取自5例患者的腹部MSCT检查,其增量变化为100% (8mm), 50% (4mm), 30% (2,4 mm)。研究结果由3名受访者评估。数据分析采用kappa统计检验、交叉校正和friedman。结果:从统计检验来看,2.4 mm增量值的结果解剖标准清晰,可检出小结节。采用friedman统计检验支持p值= 0.000,即p值为0.05,因此Ha被接受,解剖图像信息存在差异。结论:因其平均rank值最高,为2.37,因此以30% (2.4 mm)为最佳增量值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluasi Pemeriksaan MRI Brain dengan Klinis Vertigo di Rumah Sakit Otak dr. Drs. M. Hatta Bukittinggi Implementasi Pemanfaatan Sumber Radiasi Pengion pada Ruang CT Scan ditinjau berdasarkan Peraturan BAPETEN No. 4 tahun 2020 di Instalasi Radiologi Rumah Sakit type B di Wilayah Kabupaten Sumedang Nilai Entrance Skin Dose Tiroid antara menggunakan Thyroid Shield dan tanpa Thyroid Shield pada Pemeriksaan CT Scan Kepala Analisis Informasi Anatomi Pemeriksaan MRI Ankle Joint pada Penggunaan Foot Ankle Coil dan Flex Coil Proton Density Fat Saturation Irisan Sagital Evaluasi Kualitas Radiograf Periapikal Teknik Bisektris : Kesalahan Penempatan Sudut Penyinaran dan Film
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1