{"title":"Transformer less, lower THD and highly efficient inverter system","authors":"Md. Khurshedul Islam, Md. Mizanur Rahman, Md. Fazle Rabbi","doi":"10.1109/ICAEE.2015.7506853","DOIUrl":null,"url":null,"abstract":"Total Harmonic Distortion (THD) of a voltage or current signal causes power system losses, apparatus overheating and increases the power bills. This paper proposes the design and implementation of a transformer less single-phase inverter system that produces an output voltage of desired magnitude and frequency at a very lower THD. In `general inverter system', a lower DC voltage is inverted into lower AC voltage which is further boost up to distribution level through a step up transformer. This system contains higher THD. But, the `proposed inverter system' efficiently converts a 12V DC into 220V AC at a lower THD. By analysis on a real system, both topologies are simulated. Here PSIM simulation software is used. From the comparison of the simulation output, lower THD is demonstrated for `proposed inverter system' than `general inverter system'.","PeriodicalId":123939,"journal":{"name":"2015 International Conference on Advances in Electrical Engineering (ICAEE)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Advances in Electrical Engineering (ICAEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAEE.2015.7506853","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Total Harmonic Distortion (THD) of a voltage or current signal causes power system losses, apparatus overheating and increases the power bills. This paper proposes the design and implementation of a transformer less single-phase inverter system that produces an output voltage of desired magnitude and frequency at a very lower THD. In `general inverter system', a lower DC voltage is inverted into lower AC voltage which is further boost up to distribution level through a step up transformer. This system contains higher THD. But, the `proposed inverter system' efficiently converts a 12V DC into 220V AC at a lower THD. By analysis on a real system, both topologies are simulated. Here PSIM simulation software is used. From the comparison of the simulation output, lower THD is demonstrated for `proposed inverter system' than `general inverter system'.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
变压器少,THD低,逆变系统效率高
电压或电流信号的总谐波失真(THD)会导致电力系统损耗、设备过热并增加电费。本文提出了一种无变压器单相逆变器系统的设计和实现,该系统在非常低的THD下产生所需幅度和频率的输出电压。在“通用逆变器系统”中,较低的直流电压被转换成较低的交流电压,交流电压通过升压变压器进一步升压到配电水平。该系统含有较高的THD。但是,“建议的逆变器系统”可以在较低的THD下有效地将12V直流转换为220V交流。通过对实际系统的分析,对两种拓扑结构进行了仿真。这里使用了PSIM仿真软件。通过仿真输出的比较,证明了“拟议逆变系统”比“一般逆变系统”的THD更低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Problem analysis and probable solution of existing interconnected grid system of Chittagong region Development of an LCL filter for a residential Microgrid system Hardware implementation of grid connected transformer-less semi-Z-source inverter topology to mitigate common mode leakage current and THD Earthquake monitoring and warning system The next generation of irrigation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1